Capillary Zone Electrophoresis of Serum Proteins: Effects of Changed Analytical Conditions
Authors:
- Paola LuraschiPLPaola Luraschi
- Elisabetta Dalla DeaEDElisabetta Dalla Dea
- Carlo FranziniCFCarlo Franzini
- 17 January 2003
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 41 (6) , 782-6
Abstract
Analytical conditions in a system for capillary zone electrophoresis (Beckman Paragon CZE 2000) were originally selected to allow serum protein separation into five discrete protein zones, corresponding to those of conventional clinical electrophoresis. To improve the system's performance, new analytical conditions have been made available. We compared the two sets of conditions ("new" = y; "old" = x) for possible variations of results caused by the change. One hundred thirteen serum samples, covering wide intervals of values, were assayed on two twin instruments working under the old and the new conditions; results were assessed statistically and graphically. Possible clinical significance of differences was checked by comparison with the biological variation-based quality specifications for bias. Statistically significant (y-x) differences were observed for the alpha1-, alpha2- and beta-globulin zones; clinically significant differences were observed for all the zones, with the exception of the gamma-globulin zone. Therefore, old/new regression equations were calculated, whose reliability was assured by the wide interval of values, by the large sample size, and by the low dispersion of single values around the mean concordance estimates. Such equations may be used to convert "old" into "new" reference values, and for the intercomparison of patient results obtained under different analytical conditions.Keywords
This publication has 10 references indexed in Scilit:
- The Pavia Approach to Clinical Protein AnalysisClinical Chemistry and Laboratory Medicine (CCLM), 2001
- Reference Values for the Five Electrophoretic Serum Protein Fractions in Caucasian Children by Capillary Zone ElectrophoresisClinical Chemistry and Laboratory Medicine (CCLM), 2001
- Serum Proteins by Capillary Zone Electrophoresis: Approaches to the Definition of Reference ValuesClinical Chemistry and Laboratory Medicine (CCLM), 1999
- Capillary Electrophoresis in Clinical ChemistryAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1999
- Current databases on biological variation: pros, cons and progressScandinavian Journal of Clinical and Laboratory Investigation, 1999
- Prospective Study of Serum Protein Capillary Zone Electrophoresis and Immunotyping off Monoclonal Proteins by ImmunosubtractionAmerican Journal of Clinical Pathology, 1998
- Capillary Zone Electrophoresis in the Evaluation of Serum Protein AbnormalitiesAmerican Journal of Clinical Pathology, 1998
- Analysis of Method Comparison StudiesAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1996
- Quantification of Serum Proteins Using Capillary ElectrophoresisAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1995
- Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical areaScandinavian Journal of Clinical and Laboratory Investigation, 1988