Effect of Wall, Roof, and Window‐to‐Wall Ratio on the Cooling and Heating Load of a Building in India
Open Access
- 7 February 2025
- journal article
- research article
- Published by Wiley in Energy Science & Engineering
- Vol. 13 (3) , 1255-1279
Abstract
This study examines the impact of various combinations of walls, roofs, and window‐to‐wall ratios (WWRs) on the cooling and heating loads of residential buildings in India's composite climatic zone. Utilizing EnergyPlus and eQuest simulations, the thermal performance of three building types is analyzed across 32 cases involving two types of walls (W1, W2), roofs (R1, R2), and WWRs of 10%, 20%, 30%, and 40%. The results indicate that Case 29 (W2 R2 N2 WWR1), characterized by a north‐facing orientation, square‐shaped design, and a 10% WWR, achieves the lowest cooling and heating loads among all configurations. Specifically, in Building 1, this configuration reduces cooling loads by 26.0% (from 204 to 151 kBTU/h) and heating loads by 28.6% (from 224 to 160 kBTU/h) compared to the highest load scenario, Case 4 (W1 R1 N1 WWR4, west‐facing orientation, square‐shaped design, and 40% WWR). Similar trends are observed for Buildings 2 and 3. These findings underscore the critical role of optimizing building envelope parameters, particularly orientation, shape, and WWR, in achieving significant energy savings. The insights provided by this study can aid architects, engineers, and policymakers in designing energy‐efficient residential buildings.Keywords
This publication has 31 references indexed in Scilit:
- Commissioning Process and Energy Analysis in the Building: A Case Study for Ranchi City2021
- Evaluation of thermal comfort standards in office buildings of Chile: Thermal sensation and preference assessmentBuilding and Environment, 2020
- Triple bottom line sustainability assessment of window-to-wall ratio in US office buildingsBuilding and Environment, 2020
- Building energy demand assessment through heating degree days: The importance of a climatic datasetApplied Energy, 2019
- A data-driven approach to defining acceptable temperature ranges in buildingsBuilding and Environment, 2019
- Influence of glazing area on optimum thickness of insulation for different wall orientationsApplied Thermal Engineering, 2019
- Design optimisation for window size, orientation, and wall reflectance with regard to various daylight metrics and lighting energy demand: A case study of buildings in the tropicsApplied Energy, 2016
- Importance of building orientation in determining daylighting quality in student dorm rooms: Physical and simulated daylighting parameters’ values compared to subjective survey resultsEnergy and Buildings, 2014
- Energy and exergy analyses of solar drying system of red seaweedEnergy and Buildings, 2014
- Environmental performance optimization of window–wall ratio for different window type in hot summer and cold winter zone in China based on life cycle assessmentEnergy and Buildings, 2010