Extensive technique for grid‐connected converter power generation maximisation during asymmetrical grid voltages
Authors:
Open Access
- 8 August 2019
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 14 (5) , 759-770
Abstract
Short‐circuit faults and asymmetrical power production and consumption result in the appearance of unbalanced voltages. The change in voltage profiles could result in grid‐connected converter's overcurrent protection triggering if power references are kept at the pre‐disturbance level. This study provides a framework for current references calculation that can result in virtually any active and reactive power profiles that are within the domain of the converter's physical capabilities. This is accomplished by introducing three references calculation algorithms, which are all based on the same underlying concept. The first algorithm gives the grid operator the option to choose to prioritise the production of either active or reactive power and to curtail the power production only to the extent that converter's current ratings are not surpassed. Simultaneously, the oscillations in one of the powers are managed. The second approach also provides power production prioritisation feature, but here power production is realised through adjustable ratio between positive and negative current components. The third scheme is an enhancement of the previous two schemes and allows for the constant power factor to be produced before and during the disturbances. Distribution network model emulated in the hardware‐in‐the‐loop environment was used for the validation of proposed solutions.Keywords
Funding Information
- Ministarstvo Prosvete, Nauke i Tehnološkog Razvoja (III42004)
This publication has 31 references indexed in Scilit:
- Online Reference Limitation Method of Shunt-Connected Converters to the Grid to Avoid Exceeding Voltage and Current Limits Under Unbalanced Operation—Part I: TheoryIEEE Transactions on Energy Conversion, 2015
- Online Reference Limitation Method of Shunt-Connected Converters to the Grid to Avoid Exceeding Voltage and Current Limits Under Unbalanced Operation—Part II: ValidationIEEE Transactions on Energy Conversion, 2015
- Control of three-phase inverter-based DG system during fault condition without changing protection coordinationInternational Journal of Electrical Power & Energy Systems, 2014
- Reactive Power Control for Distributed Generation Power Plants to Comply With Voltage Limits During Grid FaultsIEEE Transactions on Power Electronics, 2014
- Active and Reactive Power Strategies With Peak Current Limitation for Distributed Generation Inverters During Unbalanced Grid FaultsIEEE Transactions on Industrial Electronics, 2014
- Proportional-resonant controllers and filters for grid-connected voltage-source convertersIEE Proceedings - Electric Power Applications, 2006
- Stationary frame current regulation of PWM inverters with zero steady-state errorIEEE Transactions on Power Electronics, 2003
- Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditionsIEEE Transactions on Industry Applications, 2002
- Characterisation of voltage sags experienced by three-phase adjustable-speed drivesIEEE Transactions on Power Delivery, 1997