Improved correction for gradient nonlinearity effects in diffusion‐weighted imaging
Authors:
Open Access
- 21 November 2012
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 38 (2) , 448-453
Abstract
Purpose: To provide an improved correction for gradient nonlinearity (GN) effects in diffusion‐weighted imaging (DWI). These effects produce spatially varying apparent diffusion coefficient (ADC), a result that will be significant in large field‐of‐view imaging, and may be confounded by distortion and concomitant fields related to the DWI acquisition.Materials and Methods: The effect of more accurate gradient field maps on GN correction (GNC) of ADC was evaluated. A simulation compared GN effects in commonly imaged anatomy. A temperature‐controlled phantom was imaged at positions 0 cm and 11 cm from isocenter and in two whole‐body MRI systems at 1.5T with different patient bore diameters (55 cm and 60 cm). Varying correction methods were applied to determine the errors from spatial variance and interscanner reproducibility.Results: As compared to conventional fifth‐order spherical harmonics, a seventh‐order GNC improved ADC accuracy by 1%. The combination of GNC with a dual‐spin‐echo pulse sequence and a retrospective concomitant field correction reduced ADC error due to spatial variance from 9.5% to 1.8% (55 cm bore) and from 4.2% to 1.8% (60 cm bore). The error in ADC attributed to interscanner reproducibility was reduced from 5.8% to 0.15% (at isocenter) and from 10% to 0.63% (11 cm from isocenter).Conclusion: GNC in DWI improved spatial accuracy and interscanner reproducibility of ADC. J. Magn. Reson. Imaging 2013;38:448–453.Keywords
This publication has 20 references indexed in Scilit:
- Predicting and monitoring cancer treatment response with diffusion‐weighted MRIJournal of Magnetic Resonance Imaging, 2010
- Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and RecommendationsNeoplasia, 2009
- Technology Insight: water diffusion MRI—a potential new biomarker of response to cancer therapyNature Clinical Practice Oncology, 2008
- Diffusion Magnetic Resonance Imaging: A Biomarker for Treatment Response in OncologyJournal of Clinical Oncology, 2007
- Reliability in multi-site structural MRI studies: Effects of gradient non-linearity correction on phantom and human dataNeuroImage, 2006
- Changes in Water Mobility Measured by Diffusion MRI Predict Response of Metastatic Breast Cancer to ChemotherapyNeoplasia, 2004
- Early Detection of Response to Radiation Therapy in Patients With Brain Malignancies Using Conventional and High b-Value Diffusion-Weighted Magnetic Resonance ImagingJournal of Clinical Oncology, 2003
- Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echoMagnetic Resonance in Medicine, 2002
- Concomitant gradient terms in phase contrast MR: Analysis and correctionMagnetic Resonance in Medicine, 1998
- Magnet field profiling: Analysis and correcting coil designMagnetic Resonance in Medicine, 1984