Abstract
Contrast optimization of a three-dimensional (3D) Fluid-attenuated inversion recovery (FLAIR) sequence is examined in the context of multiple sclerosis. In order to develop 3D FLAIR for enhanced detection of lesions, an iterative approach based on theoretical considerations was used. The 3D FLAIR sequence was systematically acquired with incremental parameter changes on a single subject with multiple sclerosis in a 3-T MRI scanner. Region of interest analysis was performed on the images, and the best estimate of the optimal acquisition parameters was established. This process was iterated on subsequent patients with multiple sclerosis until only marginal gains in quality were obtained. Three-dimensional FLAIR for enhanced detection produced increased lesion detection and identification in the supratentorial and infratentorial regions when compared with default GE 3D FLAIR and two-dimensional FLAIR sequences. Lesion border delineation was enhanced as evidenced by better lesion and white matter contrast ratios, demonstrating that the approach is a viable method for improved lesion detection. Magn Reson Med, 2012.Keywords
This publication has 28 references indexed in Scilit:
- 3 T MRI relaxometry detects T2 prolongation in the cerebral normal-appearing white matter in multiple sclerosisNeuroImage, 2009
- MRI in multiple sclerosis: current status and future prospectsThe Lancet Neurology, 2008
- Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivoMagnetic Resonance in Medicine, 2007
- Clinical–Magnetic Resonance Imaging Correlations in Multiple SclerosisJournal of Neuroimaging, 2005
- T1, T2 relaxation and magnetization transfer in tissue at 3TMagnetic Resonance in Medicine, 2005
- Advances in functional and structural MR image analysis and implementation as FSLNeuroImage, 2004
- MRI in multiple sclerosis: correlation with expanded disability status scale (EDSS)Multiple Sclerosis Journal, 1999
- Contrast optimization of fluid‐attenuated inversion recovery (flair) imagingMagnetic Resonance in Medicine, 1995
- Fast three‐dimensional imaging of cerebrospinal fluidMagnetic Resonance in Medicine, 1987
- Multiple field strength in vivo T1 and T2 for cerebrospinal fluid protonsMagnetic Resonance in Medicine, 1986