Comparison of sodium and potassium measurements in the emergency department by point-of-care vs. central laboratory testing
Authors:
Open Access
- 13 April 2026
- journal article
- Published by Springer Nature in Wiener klinische Wochenschrift
- Vol. 138 (21-22) , 673-677
Abstract
Summary: Background: Point-of-care testing (POCT) using blood gas analyzers provides rapid results and can reduce diagnostic delays. Discrepancies between POCT and central laboratory (CL) measurements have been observed, particularly in patients with sodium disorders. This study evaluated the agreement between POCT and CL measurements for sodium and potassium in patients with hyponatremia, normonatremia and hypernatremia. Methods: In this retrospective single-center analysis, all paired measurements of sodium and potassium performed by POCT (Radiometer ABL 90 Flex Plus) and the CL (Roche Cobas Pro ISE) within ± 2 h between January and December 2024 were included. The correlation, Bland-Altman analysis, paired tests and intraclass correlation coefficients (ICC) were used to assess agreement. Regression analysis evaluated proportional bias and ANOVA tested differences among dysnatremic and normonatremic groups. Results: A total of 6404 paired sodium and 5622 paired potassium measurements were analyzed. Sodium was 140.3 mmol/L (SD 4.5) (POCT) and 137.8 mmol/L (SD 6.6) (CL), showing a mean difference of 2.4 mmol/L (SD 1.5). The correlation was significant (r = 0.583, p < 0.001) but ICC indicated poor agreement (0.473). The ANOVA demonstrated statistically significant differences between sodium groups ( p = 0.007, effect size 0.002), indicating more pronounced deviations in hypernatremic patients. For potassium, the mean difference was 0.12 mmol/L (interquartile range, IQR 0.05–0.22 mmol/L) with good agreement (ICC = 0.85) but a significant proportional bias ( p < 0.001). Clinically relevant deviations (> 4 mmol/L sodium or > 0.5 mmol/L potassium) occurred in 8.5% and 4.5% of cases, respectively. Conclusion: While potassium showed a very strong correlation and good agreement, sodium demonstrated only moderate correlation and poor agreement according to ICC criteria. Systematic and clinically relevant deviations were frequent, particularly in dysnatremic and dyskalemic patients.Keywords
Funding Information
- Johannes Kepler University Linz
This publication has 16 references indexed in Scilit:
- Konsensusempfehlungen zur Diagnose und Therapie der Hyponatriämie der Österreichischen Gesellschaft für Nephrologie 2024Wiener klinische Wochenschrift, 2024
- Hyponatremia in the emergency departmentThe American Journal of Emergency Medicine, 2022
- Risk of Electrolyte Disorders, Syncope, and Falls in Patients Taking Thiazide Diuretics: Results of a Cross-Sectional StudyThe American Journal of Medicine, 2021
- Prevalence and impact on outcome of sodium and potassium disorders in patients with community-acquired pneumonia: A retrospective analysisEuropean Journal of Internal Medicine, 2021
- Comparison of electrolyte and glucose levels measured by a blood gas analyzer and an automated biochemistry analyzer among hospitalized patientsJournal of Clinical Laboratory Analysis, 2020
- Emergency department overcrowdingWiener klinische Wochenschrift, 2020
- Comparison of point‐of‐care and central laboratory analyzers for blood gas and lactate measurementsJournal of Clinical Laboratory Analysis, 2019
- Comparison of serum sodium levels measured by blood gas analyzer and biochemistry autoanalyzer in patients with hyponatremia, eunatremia, and hypernatremiaThe American Journal of Emergency Medicine, 2016
- Characteristics, Symptoms, and Outcome of Severe Dysnatremias Present on Hospital AdmissionThe American Journal of Medicine, 2012
- Incidence and prognosis of dysnatremias present on ICU admissionIntensive Care Medicine, 2009