Intra-pocket ultrasound-guided axillary vein puncture vs. cephalic vein cutdown for cardiac electronic device implantation: the ACCESS trial
Open Access
- 13 October 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 44 (46) , 4847-4858
Abstract
Intra-pocket ultrasound-guided axillary vein puncture (IPUS-AVP) for venous access in implantation of transvenous cardiac implantable electronic devices (CIED) is uncommon due to the lack of clinical evidence supporting this technique. This study investigated the efficacy and early complications of IPUS-AVP compared to the standard method using cephalic vein cutdown (CVC) for CIED implantation. ACCESS was an investigator-led, interventional, randomized (1:1 ratio), monocentric, controlled superiority trial. A total of 200 patients undergoing CIED implantation were randomized to IPUS-AVP (n = 101) or CVC (n = 99) as a first assigned route. The primary endpoint was the success rate of insertion of all leads using the first assigned venous access technique. The secondary endpoints were time to venous access, total procedure duration, fluoroscopy time, X-ray exposure, and complications. Complications were monitored during a follow-up period of three months after procedure. IPUS-AVP was significantly superior to CVC for the primary endpoint with 100 (99.0%) vs. 86 (86.9%) procedural successes (P = .001). Cephalic vein cutdown followed by subclavian vein puncture was successful in a total of 95 (96.0%) patients, P = .21 vs. IPUS-AVP. All secondary endpoints were also significantly improved in the IPUS-AVP group with reduction in time to venous access [3.4 vs. 10.6 min, geometric mean ratio (GMR) 0.32 (95% confidence interval, CI, 0.28–0.36), P < .001], total procedure duration [33.8 vs. 46.9 min, GMR 0.72 (95% CI 0.67–0.78), P < .001], fluoroscopy time [2.4 vs. 3.3 min, GMR 0.74 (95% CI 0.63–0.86), P < .001], and X-ray exposure [1083 vs. 1423 mGy.cm², GMR 0.76 (95% CI 0.62–0.93), P = .009]. There was no significant difference in complication rates between groups (P = .68). IPUS-AVP is superior to CVC in terms of success rate, time to venous access, procedure duration, and radiation exposure. Complication rates were similar between the two groups. Intra-pocket ultrasound-guided axillary vein puncture should be a recommended venous access technique for CIED implantation. Efficacy and safety of intra-pocket ultrasound-guided axillary vein access vs. cephalic vein cutdown for implantation of cardiac electronic devices. CVC, cephalic vein cutdown; IPUS-AVP, intra-pocket ultrasound-guided axillary vein puncture.Keywords
Funding Information
- Hospices Civils de Lyon
This publication has 37 references indexed in Scilit:
- The Use of Ultrasound to Improve Axillary Vein Access and Minimize Complications during Pacemaker ImplantationPacing and Clinical Electrophysiology, 2016
- Association of Anaesthetists of Great Britain and Ireland: Safe vascular access 2016Anaesthesia, 2016
- Guidelines for the Appropriate Use of Bedside General and Cardiac Ultrasonography in the Evaluation of Critically Ill Patients—Part ICritical Care Medicine, 2015
- Antithrombotic management in patients undergoing electrophysiological procedures: a European Heart Rhythm Association (EHRA) position document endorsed by the ESC Working Group Thrombosis, Heart Rhythm Society (HRS), and Asia Pacific Heart Rhythm Society (APHRS)EP Europace, 2015
- A new trick to a routine procedure: taking the fear out of the axillary vein stick using the 35° caudal viewEP Europace, 2015
- Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysisEP Europace, 2015
- Comparison of the Axillary Venous Approach and Subclavian Venous Approach for Efficacy of Permanent Pacemaker ImplantationCirculation Journal, 2014
- International evidence-based recommendations on ultrasound-guided vascular accessIntensive Care Medicine, 2012
- Improved 'cut-down' technique for transvenous pacemaker lead implantationEP Europace, 2010
- Ultrasound‐Guided Venous Access for Permanent Pacemaker LeadsPacing and Clinical Electrophysiology, 2006