Abstract
Plate heat exchangers have been widely used in dairy, food processing, paper/pulp, heating, ventilating, and other related industry. While single-phase flow in plate heat exchangers has been studied extensively, the industry lacks basic information on fluid flow evaporating in plate heat exchangers. This paper provides a review of heat transfer and pressure drop correlations for fluid flow evaporating in plate heat exchangers. Emphasis is placed on the application of a plate heat exchanger as an ammonia evaporator in a refrigeration system. It is shown via thorough research of related thermal–hydraulic phenomena that heat transfer and pressure drop correlations are needed for liquid ammonia flow evaporating in plate heat exchangers. The effects of plate geometry, plate material, oil/lubricant concentration, and several operating parameters on heat transfer coefficient and pressure drop for plate heat exchangers also need to be quantified.Keywords
This publication has 26 references indexed in Scilit:
- Flow boiling of R134a and ammonia in a plate heat exchangerInternational Journal of Heat and Mass Transfer, 2008
- Heat transfer and pressure drop during HFC refrigerant vaporisation inside a brazed plate heat exchangerInternational Journal of Heat and Mass Transfer, 2007
- HFC-410A vaporisation inside a commercial brazed plate heat exchangerExperimental Thermal and Fluid Science, 2007
- Refrigerant R134a vaporisation heat transfer and pressure drop inside a small brazed plate heat exchangerInternational Journal of Refrigeration, 2007
- Dimensional analysis on the evaporation and condensation of refrigerant R-134a in minichannel plate heat exchangersApplied Thermal Engineering, 2006
- Refrigerant pressure drop in chevron and bumpy style flat plate heat exchangersExperimental Thermal and Fluid Science, 2006
- Boiling of ammonia/lubricant mixture on a horizontal tube in a flooded evaporator with inlet vapor qualityExperimental Thermal and Fluid Science, 2006
- Experimental heat transfer coefficients during refrigerant vaporisation and condensation inside herringbone-type plate heat exchangers with enhanced surfacesInternational Journal of Heat and Mass Transfer, 2004
- Saturated flow boiling heat transfer and pressure drop of refrigerant R-410A in a vertical plate heat exchangerInternational Journal of Heat and Mass Transfer, 2002
- Refrigerant-oil mixtures boiling in a planar confined spaceHeat Recovery Systems and CHP, 1994