Abstract
The formation and progress of cerebral aneurysm is highly associated with hemodynamic factors and blood flow feature. In this study, comprehensive efforts are done to investigate the blood hemodynamic effects on the creation and growth of the Internal Carotid Artery. The computational fluid dynamic method is used for the visualization of the bloodstream inside the aneurysm. Transitional, non-Newtonian and incompressible conditions are considered for solving the Navier–Stokes equation to achieve the high-risk region on the aneurysm wall. OSI and WSS of the aneurysm wall are compared within different blood flow stages. The effects of blood viscosity and coiling treatment on these factors are presented in this work. Our study shows that in male patients (HCT = 0.45), changing the porosity of coiling from 0.89 with 0.79 would decreases maximum OSI up to 75% (in maximum acceleration). However, this effect is limited to about 45% for female patients (HCT = 0.35).Keywords
This publication has 49 references indexed in Scilit:
- Is There a Role for Biomechanical Engineering in Helping to Elucidate the Risk Profile of the Thoracic Aorta?The Annals of Thoracic Surgery, 2016
- Mechano-biology in the thoracic aortic aneurysm: a review and case studyBiomechanics and Modeling in Mechanobiology, 2014
- Three-dimensional sensitivity assessment of thoracic aortic aneurysm wall stress: a probabilistic finite-element study†European Journal of Cardio-Thoracic Surgery, 2013
- Impedance-based outflow boundary conditions for human carotid haemodynamicsComputer Methods in Biomechanics and Biomedical Engineering, 2012
- On the Use of In Vivo Measured Flow Rates as Boundary Conditions for Image-Based Hemodynamic Models of the Human Aorta: Implications for Indicators of Abnormal FlowAnnals of Biomedical Engineering, 2011
- Hemodynamics of Cerebral AneurysmsAnnual Review of Fluid Mechanics, 2009
- Haemodynamic simulation of aneurysm coiling in an anatomically accurate computational fluid dynamics model: technical noteNeuroradiology, 2007
- Aortic Diameter ≥5.5 cm Is Not a Good Predictor of Type A Aortic DissectionCirculation, 2007
- Validation of CFD Simulations of Cerebral Aneurysms With Implication of Geometric VariationsJournal of Biomechanical Engineering, 2006
- What is the appropriate size criterion for resection of thoracic aortic aneurysms?The Journal of Thoracic and Cardiovascular Surgery, 1997