Influence of deformed parent vessel on rupture risk of micro cerebral aneurysm: Numerical study
Open Access
- 1 December 2023
- journal article
- research article
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (12)
Abstract
One of significant impact of stent usage for the treatment of the saccular aneurysm is deformation of the parent vessel. Present study demonstrates the influence of the aneurysm deformation caused by the stent on the risk of aneurysm rupture. Computational fluid dynamic is applied for the modeling of the blood flow inside three internal carotid artery (ICA) aneurysms with different neck angles. One-way fluid–structure interaction model is applied for the interaction of the blood and vessel. Two stage of deformation is applied on the parent vessel to analyze the influence of deformation on the hemodynamic factors of wall shear stress and oscillatory shear index. Achieved results indicate that the deformation of the aneurysm by the stent significantly reduce wall shear stress is on the sac wall and decrease the risk of internal carotid artery ICA aneurysm rupture. Our finding confirm that the main effect of aneurysm deformation is reduction of the blood velocity near ostium region.Keywords
This publication has 55 references indexed in Scilit:
- Impact of uncertainties in outflow boundary conditions on the predictions of hemodynamic simulations of ascending thoracic aortic aneurysmsComputers & Fluids, 2018
- On a Diffusive Susceptible-Infected-Susceptible Epidemic Model with Mass Action Mechanism and Birth-Death Effect: Analysis, Simulations, and Comparison with Other MechanismsSIAM Journal on Applied Mathematics, 2018
- Mechanistic modeling of cutting forces and tool flank wear in the thermally enhanced turning of hardened steelThe International Journal of Advanced Manufacturing Technology, 2016
- Rhubarb attenuates blood-brain barrier disruption via increased zonula occludens-1 expression in a rat model of intracerebral hemorrhageExperimental and Therapeutic Medicine, 2016
- Effect of cutting edge modification on the tool flank wear in ultrasonically assisted turning of hardened steelProceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture, 2016
- Application of finite element method to comparing the NIR stent with the multi-link stent for narrowings in coronary arteriesActa Mechanica Solida Sinica, 2015
- Shear‐rate‐dependent rheology effects on mass transport and surface reactions in biomicrofluidic devicesAIChE Journal, 2015
- Multi-constrained optimization in ultrasonic-assisted turning of hardened steel by electromagnetism-like algorithmProceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture, 2014
- Impedance-based outflow boundary conditions for human carotid haemodynamicsComputer Methods in Biomechanics and Biomedical Engineering, 2012
- Haemodynamic simulation of aneurysm coiling in an anatomically accurate computational fluid dynamics model: technical noteNeuroradiology, 2007