Devices for Measuring Cervical Dilation During Labor: Systematic Review and Meta-analysis
- 1 April 2018
- journal article
- review article
- Published by Wolters Kluwer Health in Obstetrical & Gynecological Survey
- Vol. 73 (4) , 231-241
Abstract
Importance: Measurement of cervical dilation is one of the major indicators of labor progression. At present, the criterion standard for this evaluation is digital examination, which results are sometimes inaccurate and extremely dependent on the subject (ie, obstetrician or midwife) experience. Objective: In this systematic and meta-analysis review, the authors have gathered the vast majority of the instruments used for measuring cervical dilation and their clinical application; main features, potentialities, and the most significant constraints are underlined for each device. Evidence Acquisition: Three of the most popular databases (ie, Web of Science, PubMed, and ClinicalTrials.gov) were used to identify all available cervimeters, by using single or combinations of the following keywords: “cervical,” “dilation or dilatation,” “cervimetry,” “cervix,” “uterine,” “measurement,” “labour or labor,” “birth,” and “monitoring.” Only articles describing the design or a specific clinical application of an instrument for cervical dilation measurement during labor were selected. Results: Twenty-five articles were deeply investigated by classifying them in 4 different homogenous groups on the basis of the method proposed for measuring cervical dilation. Suitable devices have not been realized yet, and this is the reason why nowadays the gynecologist/obstetrician still evaluates labor progression by digital examination. Conclusions and Relevance: Based on a critical analysis of the selected devices, ultrasound seems to be the most promising technology for future cervimetry realization; ultrasound is accurate in distance measurement, and the behind technology can be miniaturized. However, additional studies are necessary for optimizing the technology and developing an optimal solution. Target Audience: Obstetricians and gynecologists, family physicians. Learning Objectives: After completing this activity, the learner should be better able to critique the effectiveness of digital examination, evaluate the instruments used for measuring cervical dilation and their clinical application, and choose the best solution for future cervimetry.Keywords
This publication has 21 references indexed in Scilit:
- Obstetric Care Consensus No. 1Obstetrics & Gynecology, 2014
- Simple two‐dimensional ultrasound technique to assess intrapartum cervical dilatation: a pilot studyUltrasound in Obstetrics & Gynecology, 2013
- Association between ultrasound‐based assessment of fetal head station and clinically assessed cervical dilatationUltrasound in Obstetrics & Gynecology, 2010
- Accuracy of cervical assessment in the active phase of labourBJOG: An International Journal of Obstetrics & Gynaecology, 2007
- Continuous monitoring of cervical dilatation and fetal head station during laborMedical Engineering & Physics, 2006
- Assessment of cervical dilatation during labor: a reviewEuropean Journal of Obstetrics & Gynecology and Reproductive Biology, 1991
- An ultrasonic device for continuous measurement of cervical dilation during labourUltrasonics, 1977
- Improved technique for measurement of cervical dilatationBiomedical Engineering, 1968
- CERVICAL TOCODYNAMOMETRYBJOG: An International Journal of Obstetrics & Gynaecology, 1965
- Studien ber das Verhalten des Muttermundes w hrend der Er ffnungsperiodeArchives of Gynecology and Obstetrics, 1957