Accuracy of Smartphone Video for Contactless Measurement of Hand Tremor Frequency
Authors:
- 11 November 2020
- journal article
- research article
- Published by Wiley in Movement Disorders Clinical Practice
- Vol. 8 (1) , 69-75
Abstract
Background: Computer vision can measure movement from video without the time and access limitations of hospital accelerometry/electromyography or the requirement to hold or strap a smartphone accelerometer.Objective: To compare computer vision measurement of hand tremor frequency from smartphone video with a gold standard measure accelerometer.Methods: A total of 37 smartphone videos of hands, at rest and in posture, were recorded from 15 participants with tremor diagnoses (9 Parkinson's disease, 5 essential tremor, 1 functional tremor). Video pixel movement was measured using the computing technique of optical flow, with contemporaneous accelerometer recording. Fast Fourier transform and Bland‐Altman analysis were applied. Tremor amplitude was scored by 2 clinicians.Results: Bland‐Altman analysis of dominant tremor frequency from smartphone video compared with accelerometer showed excellent agreement: 95% limits of agreement −0.38 Hz to +0.35 Hz. In 36 of 37 videos (97%), there was <0.5 Hz difference between computer vision and accelerometer measurement. There was no significant correlation between the level of agreement and tremor amplitude.Conclusion: The study suggests a potential new, contactless point‐and‐press measure of tremor frequency within standard clinical settings, research studies, or telemedicine.Keywords
This publication has 15 references indexed in Scilit:
- Computer vision of smartphone video has potential to detect functional tremorJournal of the Neurological Sciences, 2019
- Hand-Tremor Frequency Estimation in Videos2019
- Consensus Statement on the classification of tremors. from the task force on tremor of the International Parkinson and Movement Disorder SocietyMovement Disorders, 2017
- MDS clinical diagnostic criteria for Parkinson's diseaseMovement Disorders, 2015
- A Main Directional Mean Optical Flow Feature for Spontaneous Micro-Expression RecognitionIEEE Transactions on Affective Computing, 2015
- Validation of a new tool for automatic assessment of tremor frequency from video recordingsJournal of Neuroscience Methods, 2011
- Rapid tremor frequency assessment with the iPhone accelerometerParkinsonism & Related Disorders, 2011
- Accuracy of clinical diagnosis in tremulous parkinsonian patients: a blinded video studyJournal of Neurology, Neurosurgery & Psychiatry, 2010
- Histograms of oriented optical flow and Binet-Cauchy kernels on nonlinear dynamical systems for the recognition of human actions2009
- Common Misdiagnosis of a Common Neurological DisorderArchives of Neurology, 2006