Comparison of Multidetector Computed Tomography Angiography and Cholangiography Performed at 80 and 120 kVp in Live Liver Donors
Authors:
- Steffen HuberSteffen Huber
- Daniel CornfeldDCDaniel Cornfeld
- Sukru H. EmreSESukru H. Emre
- Gary M. IsraelGary M. Israel
- 1 January 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 37 (3) , 443-449
Abstract
The objective of this study was to compare the radiation exposure and image quality of contrast-enhanced multidetector computed tomography angiography (CTA) and computed tomography cholangiography (CTC) performed for living liver donor evaluation using 80 and 120 kVp. Ninety-three potential liver donors who underwent preoperative contrast-enhanced 64 multidetector CTA and CTC were retrospectively divided into 2 groups: at 80 and at 120 kVp. An institutional review board waiver was obtained. Signal-to-noise ratio and contrast-to-noise ratio of the hepatic artery and common bile duct were obtained. The dose-length product was recorded. Image quality and visibility of hepatic artery and biliary tract anatomy were evaluated. Mann-Whitney U test was used for statistical evaluation. Mean hepatic artery/common bile duct signal-to-noise ratio was 28.9/28.6 (SD, 14.2/10.0) at 80 kVp and 27.6/25.8 (SD, 8.0/6.2) at 120 kVp (P = 0.61/0.099). Mean hepatic artery/common bile duct contrast-to-noise ratio was 24.8/23.3 (SD, 12.9/8.6) at 80 kVp and 22.2/19.3 (SD, 7.7/5.0) at 120 kVp (P = 0.76/0.005). Mean CTA/CTC dose-length product was 279/281 (SD, 42/52) mGy-cm at 80 kVp and 407/451 (SD, 208/243) mGy-cm at 120 kVp (P = 0.026/0.002). Computed tomography cholangiography image quality and visibility of biliary tract anatomy were not significantly different at 80 versus 120 kVp (all P > 0.13). Computed tomography angiography image quality was significantly lower (P < 0.01), and the noise scores significantly higher (P < 0.01) at 80 versus 120 kVp, but diagnostic. Contrast-enhanced CTA and CTC performed at 80 kVp result in comparable image quality and anatomical evaluation with reduced radiation exposure when compared with 120 kVp.Keywords
This publication has 32 references indexed in Scilit:
- Detection of biliary and vascular anatomy in living liver donors: Value of gadobenate dimeglumine enhanced MR and MDCT angiographyEuropean Journal of Radiology, 2010
- Coronary Artery Calcium Scoring With Multislice Computed TomographyInvestigative Radiology, 2006
- Biliary Tract Depiction in Living Potential Liver Donors: Comparison of Conventional MR, Mangafodipir Trisodium–enhanced Excretory MR, and Multi–Detector Row CT Cholangiography—Initial ExperienceRadiology, 2004
- Dose Reduction in Pediatric CT: A Rational ApproachRadiology, 2003
- Technique of bile duct reconstruction and management of biliary complications in right lobe living donor liver transplantationClinical Transplantation, 2003
- Anatomic Variation in Intrahepatic Bile Ducts: an Analysis of Intraoperative Cholangiograms in 300 Consecutive Donors for Living Donor Liver TransplantationKorean Journal of Radiology, 2003
- Anatomical variations and surgical strategies in right lobe living donor liver transplantation: lessons from 120 cases1Transplantation, 2002
- Complications of Diagnostic and Therapeutic Ercp: A Prospective Multicenter StudyAmerican Journal of Gastroenterology, 2001
- Impact of Multidetector CT on Donor Selection and Surgical Planning Before Living Adult Right Lobe Liver TransplantationAmerican Journal of Roentgenology, 2001
- Surgical Management of Anatomical Variations of the Right Lobe in Living Donor Liver TransplantationAnnals of Surgery, 2000