In Vivo Ultrasound Thermography in Presence of Temperature Heterogeneity and Natural Motions
- 15 September 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 62 (2) , 450-457
Abstract
Real-time ultrasound thermography has been recently demonstrated on commercially available diagnostic imaging probes. In vitro experimental results demonstrate high sensitivity to small, localized temperature changes induced by subtherapeutic focused ultrasound. Most of the published results, however, are based on a thermally induced echo strain model that assumes infinitesimal change in temperature between imaging frames. Under this assumption, the echo strain is computed using a low-pass axial differentiator, which is implemented by a finite-impulse response digital filter. In this paper, we introduce a new model for temperature estimation, which employs a recursive axial filter that acts as a spatial differentiator-integrator of echo shifts. The filter is derived from first principles and it accounts for a nonuniform temperature baseline, when computing the spatial temperature change between two frames. This is a major difference from the previously proposed infinitesimal echo strain filter (δ-ESF) approach. We show that the new approach can be implemented by a first-order infinite-impulse response digital filter with depth-dependent spatial frequency response. Experimental results in vitro demonstrate the advantages over the δ-ESF approach in terms of suppressing the spatial variations in the estimated temperature without resorting to ad hoc low-pass filtering of echo strains. The performance of the new recursive echo strain filter (RESF) is also illustrated using echo data obtained during subtherapeutic localized heating in the hind limb of Copenhagen rat in vivo. In addition to the RESF, we have used an adaptive spatial filter to remove motion and deformation artifacts during real-time data collection. The adaptive filtering algorithm is described and comparisons with uncompensated estimated spatio-temporal temperature profiles are given. The results demonstrate the feasibility of in vivo ultrasound thermography with high sensitivity and specificity.Keywords
Funding Information
- National Institutes of Health (EB009750)
- Minnesota Futures
- University of Minnesota's office of Vice-President
This publication has 23 references indexed in Scilit:
- Adaptive motion compensation for in vivo ultrasound temperature estimation2013
- Ultrasound thermography in vivo: A new model for calculation of temperature change in the presence of temperature heterogeneity2013
- Real-Time Implementation of a Dual-Mode Ultrasound Array System: In Vivo ResultsIEEE Transactions on Biomedical Engineering, 2013
- Real-time monitoring of thermal and mechanical tissue response to modulated phased-array HIFU beams in vivoAIP Conference Proceedings, 2012
- Dynamic frame selection forin vivoultrasound temperature estimation during radiofrequency ablationPhysics in Medicine & Biology, 2010
- Real-Time 2-D Temperature Imaging Using UltrasoundIEEE Transactions on Biomedical Engineering, 2009
- In vivochange in ultrasonic backscattered energy with temperature in motion-compensated imagesInternational Journal of Hyperthermia, 2008
- Monitoring the formation of thermal lesions with heat-induced echo-strain imaging: A feasibility studyUltrasound in Medicine & Biology, 2005
- Noninvasive Estimation of Tissue Temperature Via High-Resolution Spectral Analysis TechniquesIEEE Transactions on Biomedical Engineering, 2005
- Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part I. Analytical modelThe Journal of the Acoustical Society of America, 1996