A capacitance-to-digital converter for displacement sensing with 17b resolution and 20μs conversion time
Authors:
- 1 February 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01936530,p. 198-200
Abstract
In precision mechatronic systems, such as wafer steppers, the position of critical mechanical components must be dynamically stabilized with sub-nanometer precision. This can be achieved by a servo loop consisting of a displacement sensor and an actuator. Compared to optical interferometers, capacitive displacement sensors offer smaller size and lower cost. However, mechanical tolerances limit their electrode spacing to about 10μm [1], while the targeted resolution is below 100pm rms . This requires a capacitance-to-digital converter (CDC) with more than 17b resolution. Furthermore, its latency must be low enough (20μs) to avoid compromising servo-loop stability. Lastly, it should be stable enough to maintain measurement accuracy during the intervals between system calibrations.Keywords
This publication has 3 references indexed in Scilit:
- A Delta–Sigma Interface Circuit for Capacitive Sensors With an Automatically Calibrated Zero PointIEEE Transactions on Circuits and Systems II: Express Briefs, 2011
- An instrument-on-chip for impedance measurements on nanobiosensors with attoFarad resoution2009
- A 2.5V 14-bit ΣΔ CMOS-SOI capacitive accelerometer2004