BIPM calibration scheme for UTC time links — BIPM pilot expermiment to strenghen Asia-Europe very long baselines
Authors:
- 1 May 2011
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23271914,p. 1-6
Abstract
The calibration uncertainty (u B ) is the dominant part in the total uncertainty budget of the UTC generation. There are two calibration strategies: (a) Receiver calibration and (b) Time link calibration. The state-of-the-art of the u B is of order 5 ns for GNSS time transfer based on the strategy (a) and is 1 ns for TWSTFT based on the strategy (b) in which the absolute offset is canceled. In the BIPM Circular T, the uncertainty in UTC-UTC(k) is obtained from the uncertainties in the links. To reduce the uncertainty in UTC-UTC(k), it is optimal to use the calibration strategy (b). Earlier investigations gave theoretical and practical proofs. Based on these studies, we propose the BIPM calibration scheme using a calibration system composed of three GNSS geodesic receivers: one is stationary at BIPM and the other two travel between the laboratories. We describe the set-up of the system, the schedule, the uncertainty u B and aging of the u B . The u B is expected to be better than 2 ns for even very long inter-continental UTC baselines.Keywords
This publication has 7 references indexed in Scilit:
- Toward new procedures in TWSTFT and GNSS delay characterization for UTC time transfer?2010
- On improved GPS-based calibration of the time links between metas and PTB2010
- Improving TWSTFT short-term stability by network time transferIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2009
- Combination of TWSTFT and GNSS for accurate UTC time transferMetrologia, 2009
- Analysis of the Asia-Pacific TWSTFT network2008
- Time transfer with nanosecond accuracy for the realization of International Atomic TimeMetrologia, 2008
- The evaluation of uncertainties in [UTC−UTC(k)]Metrologia, 2006