Effect of quaternary ammonium disinfection on image quality and structural integrity of photostimulable phosphor plates
Authors:
- Pedro Henrique Pereira Da-Silva-CostaPDPedro Henrique Pereira Da-Silva-Costa
- Débora Costa RuizDRDébora Costa Ruiz
- Tárcila Mathiasso Nascimento da SilvaTSTárcila Mathiasso Nascimento da Silva
- Rafael de Queiroz FerreiraRFRafael de Queiroz Ferreira
- Teresa Cristina Rangel PereiraTPTeresa Cristina Rangel Pereira
- Sergio Lins De-Azevedo-VazSDSergio Lins De-Azevedo-Vaz
- 15 May 2026
- journal article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (7) , 732-742
Abstract
Objectives: To evaluate the effect of quaternary ammonium compound (QAC) disinfection on the radiographic image quality and chemical integrity of photostimulable phosphor (PSP) plates. Methods: Radiographic image quality was assessed using 2 radiographs of an acrylic-block and 2 radiographs of an aluminum step-wedge acquired before disinfection and after 10 groups with 10 disinfections each. These radiographs were acquired with 2 PSP plates. Brightness, noise, uniformity, contrast, and presence of artifacts were analyzed. Analysis of variance compared gray values between disinfections (α = 0.05). Chemical integrity was assessed using mid-infrared Fourier-transform infrared (FTIR) spectroscopy on the PSP plates tube side, comparing disinfected plates with a non-disinfected control. Metal disk corrosion of the plates was visually inspected. Results: Brightness decreased after 100 disinfections compared with radiographs obtained after 20 disinfections (P = .026). Uniformity increased for all disinfection groups compared with baseline radiographs (P < .001). Radiographs obtained after 100 disinfections showed higher contrast than those acquired after 20 disinfections (P = .005). Noise did not differ (P > .05). Artifacts were observed after 40 disinfections. Fourier-transform infrared analysis showed hydration followed by degradation of the PSP plates after 100 disinfections. Metal disk corrosion occurred after 10 disinfections. Conclusions: Quaternary ammonium compound disinfection affected brightness, uniformity, contrast, produced artifacts, chemical changes, and metal disk corrosion of the PSP plates. Advances in knowledge: This study is the first to assess the impact of disinfecting PSP plates with QAC. Results showed that QAC is not a viable option since its use produced changes in image quality and integrity degradation.Keywords
Funding Information
- Espírito Santo Research and Innovation Support Foundation
This publication has 22 references indexed in Scilit:
- Peracetic acid efficacy on disinfection of photostimulable phosphor platesDentomaxillofacial Radiology, 2024
- Effect of 3 different disinfection methods on the image quality of photostimulable phosphor platesOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2023
- Disinfection of intraoral photostimulable phosphor plates with 70% ethyl alcohol and 70% isopropyl alcohol alters image contrast and produces image artifactsOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2023
- Influence of extensive use of a photostimulable phosphor receptor on the diagnosis of proximal carious lesions: An in vitro studyOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2022
- Dental restorative materials containing quaternary ammonium compounds have sustained antibacterial actionThe Journal of the American Dental Association, 2022
- Increased Use of Quaternary Ammonium Compounds during the SARS-CoV-2 Pandemic and Beyond: Consideration of Environmental ImplicationsEnvironmental Science & Technology Letters, 2020
- Cross-contamination and infection control in intraoral digital imaging: a comprehensive reviewOral Radiology, 2020
- A pilot study of the effects of a vacuum sealing barrier method for photostimulable phosphor plates regarding plate damage and prevention of microbiologic cross-contaminationOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2018
- Laser irradiation effects on the optical properties of layer-by-layer PPV/Congo Red thin filmsSynthetic Metals, 2011
- A comparison of 18 different x-ray detectors currently used in dentistryOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2005