Usefulness of quantitative Loop-Mediated Isothermal Amplification Assay in comparison with real time PCR for the diagnosis of invasive pneumococcal disease
Preprint
Abstract
Background Quantitative LAMP (qLAMP) assay is one of the recent and emerging diagnostic tests for infectious diseases. Only a few studies exist comparing this assay with quantitative real-time PCR (qPCR) for the diagnosis of invasive pneumococcal disease (IPD). The present study was performed to compare the diagnostic performance of qLAMP assay with qPCR targeting autolysin gene for the diagnosis of invasive pneumococcal disease. Methodology/Principal Findings Ninety six blood samples and 73 CSF samples from patients clinically suspected with community acquired pneumonia and acute meningitis were tested by qPCR and qLAMP assays using previously published primers and protocols. The qPCR was considered as the gold standard test and the diagnostic performance was assessed by calculating sensitivity, specificity, positive and negative predictive values, and kappa coefficient for the level of agreement between the tests. Chi-squared/Fisher exact test was used to compare categorical variables (positive/negative). Thirty two blood samples and 22 CSF samples were positive by qPCR while 24 and 20 samples were positive by qLAMP assay respectively. The sensitivity of qLAMP assay was only 86.4% and 75% when tested on CSF and blood samples respectively. However, the qLAMP assay was in substantial to almost perfect agreement when compared with qPCR. The results were statistically significant in both sample types (PConclusions The performance of qLAMP assay can vary based on the specimen type. It has very high specificity and had substantial to almost perfect agreement, and thus may be an alternative to qPCR for the diagnosis of IPD.Keywords
This publication has 11 references indexed in Scilit:
- Loop-Mediated Isothermal Amplification Methods for Diagnosis of Bacterial MeningitisFrontiers in Pediatrics, 2018
- Comparison of a loop-mediated isothermal amplification for orf virus withquantitative real-time PCRVirology Journal, 2013
- The Enhanced Pneumococcal LAMP Assay: A Clinical Tool for the Diagnosis of Meningitis Due to Streptococcus pneumoniaePLOS ONE, 2012
- Comparison of loop-mediated isothermal amplification (LAMP) and real-time PCR method targeting a 529-bp repeat element for diagnosis of toxoplasmosisVeterinary Parasitology, 2012
- Development and Evaluation of Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Rapid and Real-Time Detection of the Swine-Origin Influenza A H1N1 VirusThe Journal of Molecular Diagnostics, 2011
- Comparison of reverse transcription loop-mediated isothermal amplification, conventional PCR and real-time PCR assays for Japanese encephalitis virusMolecular Biology Reports, 2010
- Evaluation and Improvement of Real-Time PCR Assays Targeting lytA , ply , and psaA Genes for Detection of Pneumococcal DNAJournal of Clinical Microbiology, 2007
- Tolerance of loop-mediated isothermal amplification to a culture medium and biological substancesJournal of Biochemical and Biophysical Methods, 2007
- Loop-Mediated Isothermal Amplification Method Targeting the lytA Gene for Detection of Streptococcus pneumoniaeJournal of Clinical Microbiology, 2005
- Loop-mediated isothermal amplification of DNANucleic Acids Research, 2000