Abstract
We recently reported a Ca+40 optical clock comparison with an uncertainty at 5.5×10−17, mainly limited by the excess micromotion shift. Here we report the progress made to reduce this shift and its uncertainty below 1×10−18 by precise measurement of the “magic” rf drive frequency Ω0 at which the micromotion-induced scalar Stark shift and second-order Doppler shift cancel each other. Ω0 is measured as 2π×24.801(2)MHz, and the differential static scalar polarizability Δα0 of the Ca+40 ion clock transition is measured as −7.2677(21)×10−40Jm2V−2. The blackbody radiation shift is then calculated to be 0.37913(12) Hz at 300 K considering the dynamic correction. The contribution of the blackbody shift coefficient to the uncertainty of the optical clock at room temperature has been reduced to the 3×10−19 level. With further improvements made to reduce the servo error, the total clock uncertainty is reduced to 2.2×10−17, limited by the blackbody radiation field evaluation.
Funding Information
  • National Natural Science Foundation of China (91736310, 11774388, 11634013, 11622434)
  • Chinese Academy of Sciences (XDB21030100)
  • Youth Innovation Promotion Association of the Chinese Academy of Sciences (2015274, 2018364)

This publication has 34 references indexed in Scilit: