Measurement of Radiological Parameters of Distal Radius Fracture Using the Ulnar Axis Compared with the Radial Axis
Authors:
- 15 March 2024
- journal article
- research article
- Published by World Scientific Pub Co Pte Ltd in The Journal of Hand Surgery (Asian-Pacific Volume)
- Vol. 29 (02) , 140-147
Abstract
Background: The long axis of the radius is a standard reference for measuring radiological parameters in distal radius fractures. However, in patients with severe comminution and anatomical variation with distal radius bowing, it is challenging to assess using the long axis of the radius. The long axis of the ulna can be used as an alternative reference. The aim of this study is to assess the reliability and level of agreement using the long axis of the ulna as an alternative reference in comparison to the long axis of the radius. Methods: Posteroanterior (PA) radiography of the wrist in patients with acute distal radius fractures was evaluated in two rounds by four observers. Radial height, radial inclination and ulnar variance were measured using radial and ulnar long axis as references. The intraobserver and interobserver reliability of the measurements with two reference axes was assessed using intraclass correlation coefficient (ICC). The level of agreement was determined using the Bland–Altman plot. Results: In total, 59 patients who underwent PA radiography of the wrist were included in this study. All parameters exhibited good agreement between the two methods, with a mean difference of nearly zero (radial height = −0.03 mm, radial inclination = −0.14° and ulnar variance = 0.03 mm). The limits of agreement in radial height (−2.87, 2.82 mm) and ulnar variance (−0.81, 0.87 mm) were narrow. However, for the radial inclination, it was wider (−6.21, 5.94°). Intraobserver reliability between the long axis of radius and ulna (ICC = 0.85–0.99 and 0.84–0.98, respectively) was good to excellent. The interobserver reliability of each parameter was excellent (ICC = 0.94–0.97). Conclusions: The ulnar long axis can be used as an alternative reference for measuring radial height, radial inclination and ulnar variance in PA radiography of the wrist in acute distal radius fracture, particularly if the radial long axis is distorted. Level of Evidence: Level III (Diagnostic)Keywords
This publication has 13 references indexed in Scilit:
- A cadaveric study of radial and ulnar bowing in the sagittal and coronal planesJournal of Shoulder and Elbow Surgery, 2020
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- The Epidemiology of Upper Extremity Fractures in the United States, 2009Journal of Orthopaedic Trauma, 2015
- The Epidemiology of Distal Radius FracturesHand Clinics, 2012
- Radiographic imaging of the wristIndian Journal of Plastic Surgery, 2011
- Patient-perceived Outcome after Displaced Distal Radius FracturesJournal of Hand Therapy, 2007
- Essential Radiographic Evaluation for Distal Radius FracturesHand Clinics, 2005
- Validation of the extensor carpi ulnaris groove as a predictor for the recognition of standard posteroanterior radiographs of the wristThe Journal of Hand Surgery, 2002
- X-ray evaluation of radial shortening for Kienböck's diseaseThe Journal of Hand Surgery, 1992
- Prediction of instability of Codes' fracturesActa Orthopaedica, 1989