Crosslinking characterization of a polyimide: AFR700B

Authors:

Abstract
Crosslinking in AFR700B polyimide was studied using several techniques. Crosslinking could not be detected using Fourier transform infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC). Swelling in n‐methyl pyrrolidone (NMP) showed network formation occurs at cure temperatures ≥325°C (617°F), but the reaction kinetics could not be determined from the data. Dynamic mechanical analysis (DMA) studies have shown that the storage modulus (G′) increased with increasing cure temperature up to 350°C (662°F), and was constant above 350°C (662°F), indicating that crosslinking via the reverse Diels‐Alder reaction was occurring. A broad secondary transition was seen in the loss modulus (G″) curves, centered between 150 and 180°C (302 and 356°F). This secondary transition appeared at a cure temperature of 300°C (572°F) and became more dominant with increasing temperature and time. This secondary transition was not seen for cures Tg). The Arrhenius plot of the rate constant showed a break in the slope, possibly indicating a change in reaction mechanism. At 1.38 MPa (200 psi), the Tg data was too scattered to determine the kinetics.

This publication has 10 references indexed in Scilit: