Determination in Situ of Chemical Solvent Vapors in a Semiconductor Workplace with an Open Path FTIR Spectrometer
Authors:
- 1 December 1994
- journal article
- research article
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 41 (6) , 685-692
Abstract
An FTIR spectrometer having a long absorbing path in an open field mode is applied to measure the air quality of semiconductor facilities, especially for chemical solvent vapors. This spectrometer is demonstrated to be a proper instrument to monitor chemical solvents widely used in the manufacture of integrated circuits. By means of the great sensitivity accruing from the kilometer pathlength, we discovered that many residual chemical solvent vapors are released in these workplaces; the limit of detection can attain the level of parts per billion by volume. Recognized spectra of chemical solvents, such as 2‐ethoxyethyl acetate, 2‐propanol, hexamethyl disilazane, aromatic hydrocarbons, alkyl derivatives of phenol, alkyl benzene sulfonate and dimethyl sulfoxide, are calibrated qualitatively and quantitatively. The related integrated absorption coefficients (or band intensities) are listed in this paper. By examining the measured spectra, we found two chemical solvents (2‐propanoI and hexamethyl disilazane) in the workplace, at concentrations about 20‐500 ppbv in such environments.Keywords
This publication has 7 references indexed in Scilit:
- Measurement of the Taiwan Ambient Trace Gas Concentration by Kilometer-Pathlength Fourier-Transform Infrared SpectroscopyAnalytical Sciences, 1994
- Optical Remote Measurement of Toxic GasesJournal of the Air & Waste Management Association, 1992
- Field testing long-path Fourier transform infrared (FTIR) spectroscopy for measurements of atmospheric gas concentrationsRemote Sensing of Environment, 1990
- Evaluation of the Applicability of Fourier Transform Infrared (FTIR) Spectroscopy for Quantitation of the Components of Airborne Solvent Vapors in AirAIHA Journal, 1989
- Fourier transform infrared least-squares methods for the quantitative analysis of multicomponent mixtures of airborne vapors of industrial hygiene concernAnalytical Chemistry, 1989
- The Limits of Detection for the Monitoring of Semiconductor Manufacturing Gas and Vapor Emissions by Fourier Transform Infrared (FTIR) SpectroscopyAIHA Journal, 1989
- Fourier Transform Infrared (FTIR) Spectroscopy for Monitoring Semiconductor Process Gas EmissionsApplied Industrial Hygiene, 1986