Comparison of Cardiac Outputs of Major Burn Patients Undergoing Extensive Early Escharectomy: Esophageal Doppler Monitor Versus Thermodilution Pulmonary Artery Catheter
Authors:
- InSuk KwokIKInSuk Kwok
- HyunMook ChangHCHyunMook Chang
- TaeHyung HanTHTaeHyung Han
- 1 November 2004
- journal article
- research article
- Published by Wolters Kluwer Health
- Vol. 57 (5) , 1013-1017
Abstract
After major burn injury, severe hemodynamic fluctuations occur in a relatively short time, requiring invasive hemodynamic monitoring. The noninvasive esophageal Doppler monitor offers an alternative to the pulmonary artery catheter. This study compares the cardiac output of the esophageal Doppler monitor with that of a pulmonary artery catheter during the large volume shifts seen in extensive early escharectomy. This study recruited 20 critically ill, major burn patients scheduled for elective early escharectomy. A thermodilution pulmonary artery catheter and esophageal Doppler monitor probes were inserted to measure cardiac output simultaneously at regular intervals. The results were analyzed by simple linear regression and Bland and Altman plots. The analysis included 92 data pairs from 20 patients, most of whom were critically ill with major burns. Escharectomy caused large intraoperative fluid shifts. The cardiac output of the esophageal Doppler monitor correlated moderately well with the cardiac output of the pulmonary artery, although it showed a mean of 15% less than the output of the pulmonary artery catheter. The mean bias was 0.77 L/minute, and the limits of agreement were ±2.74 L/min. For major burn patients undergoing early escharectomy, the esophageal Doppler monitor allows changes in hemodynamics to be followed, but does not accurately measure the absolute values of cardiac output.Keywords
This publication has 27 references indexed in Scilit:
- Utility of esophageal Doppler as a minimally invasive hemodynamic monitor: a reviewCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2002
- Anesthesia for Major Thermal InjuryAnesthesiology, 1998
- The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III PatientsJAMA, 1996
- The role of mediators in the response to thermal injuryWorld Journal of Surgery, 1992
- Burn shock resuscitationWorld Journal of Surgery, 1992
- Noninvasive optimization of left ventricular filling using esophageal DopplerCritical Care Medicine, 1991
- Inconsistent Esophageal Doppler Cardiac Output During Acute Blood LossAnesthesiology, 1990
- Pitfalls of pulmonary artery catheterization highlighted by Doppler ultrasoundCritical Care Medicine, 1989
- Continuous hemodynamk monitoring by esophageal DopplerCritical Care Medicine, 1989
- Misled by the Wedge?Chest, 1986