Influence of the Supply Voltage Variation on the Conducted Emission in the Frequency Range up to 150 kHz Injected into the Power Grid by CFL and LED Lamps—Case Study
Open Access
- 20 March 2024
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 14 (6) , 2590
Abstract
In normal operating conditions, the mains voltage level provided by low-voltage distribution networks follows time-varying patterns within permissible limits. The statistical characterisation of disturbances inserted into the power grid by nonlinear electrical devices is useful since operators are able to establish power quality limits and assess the residual capacity of networks for new smart installations, which may include a multitude of power electronic devices. Existing standards related to emission tests recommend using a power supply source in the measurement circuit with a nominal voltage parameter. However, the range of permissible variations of relevant supply voltage parameters may have an impact on conducted emissions. It can also be considered that the symptoms of supply voltage variations may manifest themselves differently depending on the equipment’s architecture and also the range of frequency observation with reference to harmonics and supraharmonics. The purpose of this study is to measure and analyze non-intentional conducted emissions injected into the power grid by lighting devices, methodically, by numbers of studies under different supply voltage conditions within two frequency bands. The emission is evaluated separately in two ranges: up to 2 kHz and 9-150 kHz. Obtained results show that the level of conducted emission introduced into the low voltage network by modern lighting sources like fluorescent and LED lamps varies with the supply voltage level compared to the emission generated in the nominal voltage level condition. Additionally, in the case of a spectrum of higher frequencies, some trends of shifting of the characteristic frequency bands are recorded. The potential of the obtained results is to complement the knowledge of the emission of modern lighting sources, which can be further used for digital models of these devices and to estimate the impact on the grid under real working conditions.Keywords
Funding Information
- Faculty of Electrical Engineering of the Wroclaw University of Science and Technology (8211104160)
This publication has 47 references indexed in Scilit:
- Sources of Non-Intentional Supraharmonics in LV Network and Its Impact on OSGP PLC Communication – Experimental StudyIEEE Transactions on Power Delivery, 2022
- Supraharmonics in Power Grid: Identification, Standards, and Measurement TechniquesIEEE Access, 2021
- Diagnosis of supraharmonics-related problems based on the effects on electrical equipmentElectric Power Systems Research, 2021
- Impact of high-frequency harmonics (0–9 kHz) generated by grid-connected inverters on distribution transformersInternational Journal of Electrical Power & Energy Systems, 2020
- Power Quality in Microgrids Including Supraharmonics: Issues, Standards, and MitigationsIEEE Access, 2020
- Summation law for supraharmonic currents (2–150 kHz) in low-voltage installationsElectric Power Systems Research, 2020
- Survey of supraharmonic emission of household appliancesCIRED - Open Access Proceedings Journal, 2017
- Impact on power quality due to large-scale adoption of compact fluorescent lamps – a reviewInternational Journal of Ambient Energy, 2016
- Energy savings analysis and harmonics reduction for the electronic ballast of T5 fluorescent lamp in a building's lighting systemEnergy and Buildings, 2015
- Low-Voltage Distribution Line Performance Evaluation for PLC Signal TransmissionIEEE Transactions on Power Delivery, 2008