Electroretinography in the Collared Scops Owl (Otus lettia)
Open Access
- 10 June 2026
- journal article
- research article
- Published by MDPI AG in Veterinary Sciences
- Vol. 13 (6) , 570
Abstract
Electroretinography (ERG) is a non-invasive technique used to assess retinal function via electrical responses to light stimuli. We established baseline ERG parameters and a standardized recording protocol for collared scops owls (Otus lettia). Twelve eyes of six owls were evaluated. In addition to the pre-release assessment, ocular reflex tests and basic ophthalmic examinations were performed before the induction of anesthesia. Routine radiographic and hematological examinations were performed under general anesthesia, followed by ERG recordings. Under scotopic –20 dB conditions, the a-wave amplitude was 1.78 ± 0.53 μV (implicit time: 37.83 ± 5.52 ms), and the b-wave was 41.59 ± 10.71 μV (100.88 ± 10.9 ms). For scotopic 0 dB mixed responses, the a-wave amplitude was 27.98 ± 5.9 μV (27.64 ± 2.71 ms), and that of the b-wave was 175.51 ± 13.82 μV (97.02 ± 7.01 ms). Under photopic conditions, the a-wave and b-wave amplitudes were 2.88 ± 2.06 μV (28.67 ± 2.77 ms) and 25.53 ± 10.61 μV (77.78 ± 16.18 ms). To the best of our knowledge, this is the first study to establish species-specific baseline ERG parameters for collared scops owls. These findings provide a valuable tool for assessing retinal function in raptors and may serve as a baseline framework for ERG evaluation in other avian species.Keywords
This publication has 32 references indexed in Scilit:
- ERG shrinks by 10% when reducing dark adaptation time to 10 min, but only for weak flashesDocumenta Ophthalmologica, 2020
- Guidelines for clinical electroretinography in the dog: 2012 updateDocumenta Ophthalmologica, 2013
- Clinical utility of a complete diagnostic protocol for the ocular evaluation of free‐living raptorsVeterinary Ophthalmology, 2011
- Clinical Techniques: Considerations for Release of Raptors with Ocular DiseaseJournal of Exotic Pet Medicine, 2007
- Influence of Recording Electrode Type and Reference Electrode Position on the Canine ElectroretinogramDocumenta Ophthalmologica, 2005
- Guidelines for clinical electroretinography in the dogDocumenta Ophthalmologica, 2002
- A practical method to obtain reproducible binocular electroretinograms in dogsDocumenta Ophthalmologica, 2002
- Propofol influences the electroretinogram to a lesser degree than thiopentoneActa Anaesthesiologica Scandinavica, 1996
- Electroretinographic changes in aged pigeonsVision Research, 1991
- The electroretinogram of the little owl (Athene noctua)Vision Research, 1989