Repositioning Rates of Toric IOLs Implanted in Cataract Surgery Patients: A Retrospective Chart Review
Author:
Open Access
- 1 December 2023
- journal article
- review article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 4001-4007
Abstract
Purpose: To determine the incidence of postoperative repositioning of toric intraocular lenses (IOLs) due to clinically significant rotation. Patients and Methods: This study included consecutive cataract patients with pre-existing astigmatism who had undergone cataract surgery with toric IOL implantation by a single experienced surgeon. Case records of patients who were recommended to undergo toric IOL repositioning surgery due to clinically significant postoperative IOL rotation from the implanted axis were identified. The need for a secondary intervention to manage residual astigmatism was based upon postoperative residual astigmatic error ≥ 0.75 D, the patient’s qualitative dissatisfaction with the level of postoperative distance vision, dilated post-op examination, and confirmation of the significant potential for astigmatism reduction. Results: Case records of 993 eyes implanted with AcrySof toric (N = 362), Tecnis Toric I (N = 53), Tecnis Toric II (N = 308), or enVista Toric IOLs (N = 270) were included. Postoperative toric IOL repositioning was recommended in 16 eyes (1.6%). The repositioning rate was highest in the eyes implanted with Tecnis Toric I (5.7%), followed by AcrySof Toric (2.2%), enVista Toric IOLs (1.1%), and Tecnis Toric II (0.6%). Conclusion: This real-world analysis of eyes implanted with toric IOLs revealed that the rate of surgical IOL repositioning due to clinically significant IOL rotation was lower than 2% for enVista and Tecnis Toric II IOLs. When needed and with appropriate planning, toric IOL repositioning can be very successful.Keywords
This publication has 23 references indexed in Scilit:
- Axis Misalignment of Toric Intraocular Lens: Placement Error and Postoperative RotationOphthalmology, 2017
- Randomized controlled clinical trial to evaluate different intraocular lenses for the surgical compensation of low to moderate-to-high regular corneal astigmatism during cataract surgeryJournal of Cataract & Refractive Surgery, 2015
- Factors influencing 1-year rotational stability of AcrySof Toric intraocular lensesBritish Journal of Ophthalmology, 2015
- Evaluation of Rotation and Visual Outcomes After Implantation of Monofocal and Multifocal Toric Intraocular LensesJournal of Refractive Surgery, 2015
- Long-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatismJournal of Cataract & Refractive Surgery, 2014
- Rotational stability of a toric intraocular lens: Influence of axial length and alignment in the capsular bagJournal of Cataract & Refractive Surgery, 2012
- The AcrySof Toric Intraocular Lens in Subjects with Cataracts and Corneal AstigmatismOphthalmology, 2010
- Repositioning technique and rate for toric intraocular lensesJournal of Cataract & Refractive Surgery, 2009
- Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lensesJournal of Cataract & Refractive Surgery, 2008
- Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantationJournal of Cataract & Refractive Surgery, 2008