Increased Rate of Catheter-Related Bloodstream Infection Associated With Use of a Needleless Mechanical Valve Device at a Long-Term Acute Care Hospital
- 1 June 2007
- journal article
- research article
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 28 (6) , 684-688
Abstract
Objective.: To determine whether introduction of a needleless mechanical valve device (NMVD) at a long-term acute care hospital was associated with an increased frequency of catheter-related bloodstream infection (BSI).Design.: For patients with a central venous catheter in place, the catheter-related BSI rate during the 24-month period before introduction of the NMVD, a period in which a needleless split-septum device (NSSD) was being used (hereafter, the NSSD period), was compared with the catheter-related BSI rate during the 24-month period after introduction of the NMVD (hereafter, the NMVD period). The microbiological characteristics of catheter-related BSIs during each period were also compared. Comparisons and calculations of relative risks (RRs) with 95% confidence intervals (CIs) were performed using χ2 analysis.Results.: Eighty-six catheter-related BSIs (3.86 infections per 1,000 catheter-days) occurred during the study period. The rate of catheter-related BSI during the NMVD period was significantly higher than that during the NSSD period (5.95 vs 1.79 infections per 1,000 catheter-days; RR, 3.32 [95% CI, 2.88–3.83]; P < .001). A significantly greater percentage of catheter-related BSIs during the NMVD period were caused by gram-negative organisms, compared with the percentage recorded during the NSSD period (39.5% vs 8%; P = .007). Among catheter-related BSIs due to gram-positive organisms, the percentage caused by enterococci was significantly greater during the NMVD period, compared with the NSSD period (54.8% vs 13.6%; P = .004). The catheter-related BSI rate remained high during the NMVD period despite several educational sessions regarding proper use of the NMVD.Conclusions.: An increased catheter-related BSI rate was temporally associated with use of a NMVD at the study hospital, despite several educational sessions regarding proper NMVD use. The current design of the NMVD may be unsafe for use in certain patient populations.Keywords
This publication has 12 references indexed in Scilit:
- Disinfection of Needleless Catheter Connectors and Access Ports With Alcohol May Not Prevent Microbial Entry: The Promise of a Novel Antiseptic-Barrier CapInfection Control & Hospital Epidemiology, 2006
- Increased Catheter-Related Bloodstream Infection Rates After the Introduction of a New Mechanical Valve Intravenous Access PortInfection Control & Hospital Epidemiology, 2006
- The Promise of Novel Technology for the Prevention of Intravascular Device–Related Bloodstream Infection. I. Pathogenesis and Short‐Term DevicesClinical Infectious Diseases, 2002
- Occupational Exposures to Body Fluids among Medical Students: A Seven-Year Longitudinal StudyAnnals of Internal Medicine, 1999
- Increased Bloodstream Infection Rates in Surgical Patients Associated with Variation from Recommended Use and Care following Implementation of a Needleless DeviceInfection Control & Hospital Epidemiology, 1998
- Bloodstream infections in home infusion patients: The influence of race and needleless intravascular access devicesThe Journal of Pediatrics, 1996
- Efficacy and cost-effectiveness of a needleless intravenous access systemAmerican Journal of Infection Control, 1995
- Evaluation and implementation of a needleless intravenous system: Making needlesticks a needless problemAmerican Journal of Infection Control, 1993
- Impact of a needleless intravenous system in a university hospitalAmerican Journal of Infection Control, 1992
- Rates of Needle-Stick Injury Caused by Various Devices in a University HospitalNew England Journal of Medicine, 1988