Characterization of a Micro Capillary Zone Electrophoresis System With Integrated Amorphous Silicon Based Optical Detectors
- 1 January 2007
- journal article
- Published by Springer Nature in MRS Proceedings
- Vol. 1004
Abstract
Application specific Lab-on-Microchips (ALMs) making use of the combination of complex microfluidic networks with microelectronic circuits and micro optical components allow the realization of miniaturized application specific biological and chemical processing and analysis devices. Fluorescence sensing is one of the most widely used detection technologies, e.g. for DNA fluorescence labelling in Micro Capillary Electrophoresis (µCE) due to its superior sensitivity and specificity. Unfortunately, commercially available fluorescence sensing systems are physically very large, non portable, expensive and constrain the analysis in portable diagnostic and medical care. Integrated semiconductor optoelectronic devices can provide a portable, parallel and inexpensive solution for on chip fluorescence sensing.Most µCE applications working in the spectral range of visible light. For the integration of optical detection components a photon energy range of 1.6 eV - 3.1 eV is of interest. The a-Si:H technology accomplished due to the low dark current and high absorption coefficient against to crystalline silicon the requirements in that spectral range. In this paper we combine a:Si-H photo sensors with a fluidic micro system to detect the fluorescence of a rhodamine analyte mixture. The analyte mixture was excited by light with a wavelength in the range of λEx = 450 - 490 nm. The a-Si:H detector reveals a low dark current density on the order of 10-10 A/cm2 and a sufficient dynamic range of ∼100 dB under illumination of ∼1000 lx as a function of bias voltage. The measurement shows that the movement of the rhodamine plug in the microchannel causes a significant rise in the pin-diode photo current, which correlates to the evaluated signal of a microscope image detector. The photo current difference for excitation and additional fluorescence amounts to 2.4 µA.Keywords
This publication has 13 references indexed in Scilit:
- On‐capillary derivatization and analysis of amino acids in human plasma by capillary electrophoresis with laser‐induced fluorescence detection: Application to diagnosis of aminoacidopathiesElectrophoresis, 2006
- A simple microfluidic system for efficient capillary electrophoretic separation and sensitive fluorimetric detection of DNA fragments using light-emitting diode and liquid-core waveguide techniquesElectrophoresis, 2005
- Characterization of SU-8 for electrokinetic microfluidic applicationsLab on a Chip, 2005
- Recent developments in detection for microfluidic systemsElectrophoresis, 2004
- Integrated Hydrogenated Amorphous Si Photodiode Detector for Microfluidic Bioanalytical DevicesAnalytical Chemistry, 2003
- Advances in on-chip photodetection for applications in miniaturized genetic analysis systemsJournal of Micromechanics and Microengineering, 2003
- FocusLab on a Chip, 2003
- Vertically integrated sensors for advanced imaging applicationsIEEE Journal of Solid-State Circuits, 2000
- Bias sensitive a-Si(C): H multispectral detectorsIEEE Transactions on Electron Devices, 1998
- Miniaturized total chemical analysis systems: A novel concept for chemical sensingSensors and Actuators B: Chemical, 1990