Contactless passive diagnosis for brain intracranial applications: A study using dielectric matching materials
- 16 June 2010
- journal article
- research article
- Published by Wiley in Bioelectromagnetics
- Vol. 31 (5) , 335-349
Abstract
A prototype system for passive intracranial monitoring using microwave radiometry is proposed. It comprises an ellipsoidal conductive wall cavity to achieve beamforming and focusing, in conjunction with sensitive multiband receivers for detection. The system has already shown the capability to provide temperature and/or conductivity variations in phantoms and biological tissue. In this article, a variant of the initially constructed modality is theoretically and experimentally investigated. Specifically, dielectric matching materials are used in an effort to improve the system's focusing attributes. The theoretical study investigates the effect of dielectric matching materials on the system's detection depth, whereas measurements with phantoms focus on the investigation of the system's detection level and spatial resolution. The combined results suggest that the dielectric matching layers lead to the improvement of the system's detection depth and temperature detection level. Also, the system's spatial resolution is explored at various experimental setups. Theoretical and experimental results conclude that with the appropriate combination of operation frequencies and dielectric layers, it is possible to monitor areas of interest inside human head models with a variety of detection depths and spatial resolutions. Bioelectromagnetics 31:335–349, 2010.Keywords
This publication has 30 references indexed in Scilit:
- Characterization of a digital microwave radiometry system for noninvasive thermometry using a temperature-controlled homogeneous test loadPhysics in Medicine & Biology, 2008
- FDTD Study of the Focusing Properties of a Hybrid Hyperthermia and Radiometry Imaging System using a Realistic Human Head Model2007
- Time-Dependent Microwave Radiometry for the Measurement of Temperature in Medical ApplicationsIEEE Transactions on Microwave Theory and Techniques, 2004
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- Microwave radiometry in living tissue: what does it measure?IEEE Transactions on Biomedical Engineering, 1992
- Functional Mapping of the Human Visual Cortex by Magnetic Resonance ImagingScience, 1991
- Mapping human visual cortex with positron emission tomographyNature, 1986
- The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologistMedical & Biological Engineering & Computing, 1967
- Intracerebral temperatures in free-moving catsAmerican Journal of Physiology-Legacy Content, 1966
- Hypothalamic temperature in unanesthetized albino rats during feeding and sleepingAmerican Journal of Physiology-Legacy Content, 1964