Luminex MFI—Efforts from a Qualitative to a Quantitative Analysis
Open Access
Abstract
The Luminex multiplex assay for the definition of HLA antibodies was introduced 20 years ago. To date, although the assay is simple and straightforward, the interpretation of the results remains a conundrum. Making use of the so-called mean fluorescence value only does not help since this value is relative, the day-to-day variation is significantly large, and the user variation is beyond acceptable ranges. Within the same range of problems, the cutoff value used to classify HLA-specific antibodies as being either present or absent varies between laboratories. This threshold influences clinical decision-making. In addition, the readout value is used to diagnose the amount of HLA-specific antibodies after treatments like absorption, plasmapheresis, or transplantation, overlooking the relative nature of the value. In this study, we show bead variability for HLA class I and HLA class II based on negatively defined bead reactions with a mean fluorescence value below 1500 and self-antigens. In an effort to circumvent the assay’s inherent problems, we introduced the term ratio. For each serum sample, a paired sample from before the treatment is run in parallel. The ratio of post-treatment to pre-treatment can then be used to characterize antibody dynamics: a ratio above 1 reflects increased antibody production and a ratio below 1 indicates a decrease in antibodies in the serum. This value may offer the possibility to make more informed and adaptive treatment decisions.Keywords
This publication has 16 references indexed in Scilit:
- Antibody Course and Memory B-Cell Response in the First Year After Severe Acute Respiratory Syndrome Coronavirus 2 InfectionThe Journal of Infectious Diseases, 2022
- Measuring anti-HLA antibody active concentration and affinity by surface plasmon resonance: Comparison with the luminex single antigen flow beads and T-cell flow cytometry crossmatch resultsMolecular Immunology, 2019
- Understanding solid-phase HLA antibody assays and the value of MFIHuman Immunology, 2017
- Concordance and discordance in anti-HLA antibody testingTransplant Immunology, 2015
- Comprehensive Assessment and Standardization of Solid Phase Multiplex-Bead Arrays for the Detection of Antibodies to HLAAmerican Journal of Transplantation, 2013
- Prediction of organ transplant rejection by HLA‐specific and non‐HLA antibodies – brief literature reviewInternational Journal of Immunogenetics, 2012
- Clinical relevance of circulating donor-specific HLA antibodiesCurrent Opinion in Organ Transplantation, 2010
- Solid phase HLA antibody detection technology - challenges in interpretationTissue Antigens, 2010
- Review article: Luminex technology for HLA antibody detection in organ transplantationNephrology, 2009
- Humoral Theory of TransplantationAmerican Journal of Transplantation, 2003