Physical Tests of Alternative Connections of Different High Roof Purlins Regarding Upward Loading
Open Access
Abstract
Thin-walled cold-rolled sections are used in the construction industry, especially in the roofing of large-span halls. The load-bearing capacity of a thin-walled structure depends to a large extent on the load-bearing capacity of the details at the point of attachment to the structure and the interconnection of the individual thin-walled elements. Therefore, in the case of thin-walled structures, it is necessary to use additional structural elements such as local reinforcement, stabilising elements, supports, and other structural measures such as the doubling of profiles. This paper focused on the behaviour of tall Z300 and Z350 mm thin-walled trusses at the connection to the superstructure regarding upward loading (e.g., wind suction and so on). Two section thicknesses, 1.89 mm and 2.85 mm, were experimentally analysed. Furthermore, two types of connections were prepared, more precisely without and with a reinforced buckle. The experiments aimed to investigate the behaviour and load-carrying capacity of the detail of the roof truss connections to the supporting structure. The resulting load capacity values were compared with normative approaches. Analyses of the details of the bolt in the connection are also presented. The paper presents a practical evaluation of the physical test on real structural members.Keywords
This publication has 13 references indexed in Scilit:
- Damage Analysis and Evaluation of Light Steel Structures Exposed to Wind HazardsApplied Sciences, 2017
- Numerical Modelling of Thin-walled Purlins Connection to the Supporting StructureProcedia Engineering, 2017
- Experimental studies of thin-walled steel roof battens subject to pull-through failuresEngineering Structures, 2016
- Optimum design of cold-formed thin-walled sections subjected to axial and bi-axial bending using artificial bee colony algorithmResearch on Engineering Structures and Materials, 2016
- Numerical study of purlin joints with sleeve connectionsThin-Walled Structures, 2015
- Numerical Modeling of a Thin-Walled Profile with respect to the Redistribution of Bending Moments2015
- An experimental study on clinched joints realized with different diesThin-Walled Structures, 2014
- Numerical investigation of cold-formed lapped Z purlins under combined bending and shearJournal of Constructional Steel Research, 2014
- Rotational stiffness of cold-formed steel roof purlin–sheeting connectionsEngineering Structures, 2014
- Research reportInternational Journal of Environmental Studies, 1973