Accurate, noninvasive quantitation of expiratory gas leak from uncuffed infant endotracheal tubes
Authors:
- 1 January 1990
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 9 (1) , 55-60
Abstract
Accurate measurement of expiratory gas leak from uncuffed infant endotracheal tubes is an important requirement for evaluating the rates of metabolic gas exchange by indirect calorimetry in neonates receiving mechanical ventilation. The present study reports a new, noninvasive technique for the efficient collection and analysis of expiratory gases leaked from a closed-circuit metabolic monitoring system recently described. A loose-fitting face mask is placed over the infant's endotracheal appliance and air is entrained from the mask cavity at 100 mL/min for CO2 analysis by infrared capnometry. In vitro calibration of this apparatus demonstrates a relative error of less than 5% of simulated endotracheal tube leak. In vivo application to metabolic rate assessment (using the MGM Jr. metabolic cart) in 12 intubated, ventilated infants ranging from 1.56 to 4.07 kg study weight demonstrated endotracheal tube leaks from 0.49 to 7.40% of net CO2 production, which ranged 10.67 to 70.91 mL/min (or mean 8.22 ± 0.93 SEM mL/kg/min). The magnitude of tube leakage of mixed expiratory gases could not be predicted from endotracheal tube diameter, ventilator settings, or infant activity or posture. As new instrumentation becomes available to measure the rates of metabolic gas exchange in intubated infants, systematic evaluation of uncuffed endotracheal tube gas leaks becomes critical. Pediatr Pulmonol. 1990; 9:55–60.Keywords
This publication has 11 references indexed in Scilit:
- Effects of intravenous glucose loading on oxygen consumption, carbon dioxide production, and resting energy expenditure in infants with bronchopulmonary dysplasiaThe Journal of Pediatrics, 1989
- Optimal Thermal Management for Low Birth Weight Infants Nursed Under High-Powered Radiant WarmersPediatrics, 1987
- The Accuracy and Precision of an Open-Circuit System To Measure Oxygen Consumption and Carbon Dioxide Production in NeonatesPediatric Research, 1986
- The Immature Rat Small Intestine Exhibits an Increased Sensitivity and Response to Escherichia coli Heat-Stable EnterotoxinPediatric Research, 1986
- Factors affecting leak around tracheal tubes in childrenCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1985
- Partitioning of Heat Losses and Gains in Premature Newborn Infants Under Radiant WarmersPediatrics, 1985
- A Double-Walled Incubator Alters the Partition of Body Heat Loss of Premature InfantsPediatric Research, 1983
- Effects of forced convection of heated air on insensible water loss and heat loss in preterm infants in incubatorsThe Journal of Pediatrics, 1982
- A Method for Measuring Functional Residual Capacity in Neonates with Endotracheal TubesIEEE Transactions on Biomedical Engineering, 1978
- Neutral Temperature Range and Range of “Thermal Comfort” in Premature InfantsNeonatology, 1962