Effect of DC-Link Voltage Limitation on Postfault Steady-State Performance of Asymmetrical Six-Phase Induction Machines
- 23 January 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 65 (9) , 6890-6900
Abstract
The asymmetrical six-phase induction machine represents the most common multiphase machine type used in many high-power industrial applications. While a body of research covering control of the machine under fault conditions has been published in the literature, corresponding studies to investigate the dc-link voltage design requirements under postfault operation in a simple and efficient manner have not met the same interest. To this end, this paper first introduces the machine steady-state equivalent circuit under one open-phase fault, which simplifies the estimation of different machine characteristic curves instead of using tedious mathematical techniques. As far as the machine parameters are concerned in this paper, a modified locked-rotor test based on the derived equivalent circuit is also proposed to fully estimate the parameters of different subspaces using a simple technique without the need for additional tests. The proposed steady-state circuit is also used to understand the effect of the secondary subspace impedance, neutral configuration, and the postfault control strategy on the maximum achievable torque for a limited dc-bus voltage. The minimum dc-link voltage magnitude to provide rated output under postfault operation is also given. The proposed concepts have been experimentally verified using a prototype asymmetrical six-phase machine.Keywords
This publication has 20 references indexed in Scilit:
- Current Harmonic Compensation for $n$ -Phase Machines With Asymmetrical Winding Arrangement and Different Neutral ConfigurationsIEEE Transactions on Industry Applications, 2017
- Parameter Estimation of Asymmetrical Six-Phase Induction Machines Using Modified Standard TestsIEEE Transactions on Industrial Electronics, 2017
- A Nine-Phase Six-Terminal Concentrated Single-Layer Winding Layout for High-Power Medium-Voltage Induction MachinesIEEE Transactions on Industrial Electronics, 2016
- Steady-State Equivalent Circuit of Five-Phase Induction Machines with Different Stator Connections under Open Line ConditionsIEEE Transactions on Industrial Electronics, 2016
- Six-Phase Induction Machine Model for Electrical Fault Simulation Using the Circuit-Oriented MethodIEEE Transactions on Industrial Electronics, 2015
- Optimal Fault-Tolerant Control of Six-Phase Induction Motor Drives With Parallel ConvertersIEEE Transactions on Industrial Electronics, 2015
- Calculation of derating factors based on steady-state unbalanced multiphase induction machine model under open phase(s) and optimal winding currentsElectric Power Systems Research, 2014
- Multiphase Electric Machines for Variable-Speed ApplicationsIEEE Transactions on Industrial Electronics, 2008
- A New PWM Strategy Based on a 24-Sector Vector Space Decomposition for a Six-Phase VSI-Fed Dual Stator Induction MotorIEEE Transactions on Industrial Electronics, 2008
- Analytical Determination of DC-Bus Utilization Limits in Multiphase VSI Supplied AC DrivesIEEE Transactions on Energy Conversion, 2008