Low-dose dobutamine stress gated blood pool SPECT assessment of left ventricular contractile reserve in ischemic cardiomyopathy: a feasibility study
Authors:
- Sergey L. AndreevSASergey L. Andreev
- Andrew S. PryakhinAPAndrew S. Pryakhin
- Andrew V. MochulaAMAndrew V. Mochula
- Alina N. MaltsevaAMAlina N. Maltseva
- Svetlana I. SazonovaSSSvetlana I. Sazonova
- Vladimir M. ShipulinVSVladimir M. Shipulin
- Samia MassalhaSMSamia Massalha
- Konstantin V. ZavadovskyKZKonstantin V. Zavadovsky
- 12 February 2022
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 49 (7) , 2219-2231
Abstract
Purpose The purpose of the present study was to evaluate the feasibility of gated blood pool single-photon emission computed tomography (GBPS) with low-dose dobutamine (LDD) stress test, performed on a single-photon emission computed tomography (SPECT) camera equipped with cadmium-zinc-telluride (CZT) solid-state detectors, in assessing of left ventricle (LV) contractile reserve in patients with ischemic cardiomyopathy (ICM). Methods A total of 52 patients (age 59 ± 7.2 years, 47 men and 5 women) with ICM and a control group of 10 patients without obstructive coronary artery lesion underwent GBPS and transthoracic echocardiography (TTE) at rest and during LDD stress test (5, 10, 15 µg/kg/min). The duration of each GBPS step was 5 min. Stress-induced changes in LV ejection fraction (ΔLVEF), peak ejection rate, LV volumes, and mechanical dyssynchrony (phase histogram standard deviation, phase histogram bandwidth and entropy) obtained with GBPS were estimated. Results All GBPS indices except end-diastolic volume showed significant dynamics during stress test in both groups. The majority of parameters in ICM patients showed significant changes at a dobutamine dose of 10 µg/kg/min as compared to the rest study. Seventeen percent of ICM patients, but none from the control group, showed a decrease in LVEF during stress, accompanied by a significant increase in entropy. The intra- and inter-observer reproducibility was excellent for both rest and stress studies. There was a moderate correlation (r = 0.5, p = 0.01) between GBPS and TTE, with a mean difference value of − 1.7 (95% confidence interval − 9.8; 6.4; p = 0.06) in ΔLVEF. Conclusion Low-dose dobutamine stress GBPS performed with high-efficiency CZT-SPECT cameras can be performed for evaluating stress-induced changes in LV contractility and dyssynchrony with lower acquisition time. A dobutamine dose of 10 µg/kg/min can potentially suffice to detect stress-induced changes in patients with ICM during GBPS. Trial registration ClinicalTrials.gov identifier: NCT04508608 (August 7, 2020).Keywords
All Related Versions
This publication has 60 references indexed in Scilit:
- Post-stress left ventricular ejection fraction drop in patients with diabetes: a gated myocardial perfusion imaging studyBMC Cardiovascular Disorders, 2013
- Low-dose dobutamine induces left ventricular mechanical dyssynchrony in patients with dilated cardiomyopathy and a narrow QRS: A study using real-time three-dimensional echocardiographyJournal of Cardiology, 2013
- Association of left ventricular mechanical dyssynchrony with survival benefit from revascularization: a study of gated positron emission tomography in patients with ischemic LV dysfunction and narrow QRSEuropean Journal of Nuclear Medicine and Molecular Imaging, 2012
- Effect of tracer dose on left ventricular mechanical dyssynchrony indices by phase analysis of gated single photon emission computed tomography myocardial perfusion imagingJournal of Nuclear Cardiology, 2012
- Evaluation of baseline contractile reserve vs dyssynchrony as a predictor of functional improvement and long term outcome after resynchronization pacing therapy: A radionuclide stress studyJournal of Nuclear Cardiology, 2012
- Left ventricular diastolic dyssynchrony assessed with phase analysis of gated myocardial perfusion SPECT: a comparison with tissue Doppler imagingEuropean Journal of Nuclear Medicine and Molecular Imaging, 2011
- Importance of dynamic dyssynchrony in the occurrence of hypertensive heart failure with normal ejection fractionEuropean Heart Journal, 2010
- Equilibrium radionuclide angiocardiographyJournal of Nuclear Cardiology, 2006
- Dynamic Ventricular DyssynchronyJACC, 2006
- Accuracy of the automated assessment of left ventricular function with gated perfusion SPECT in the presence of perfusion defects and left ventricular dysfunction: Correlation with equilibrium radionuclide ventriculography and echocardiographyJournal of Nuclear Cardiology, 2000