Estimation of stride-by-stride spatial gait parameters using inertial measurement unit attached to the shank with inverted pendulum model
Authors:
Open Access
- 14 January 2021
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-10
Abstract
Inertial measurement unit (IMU)-based gait analysis systems have become popular in clinical environments because of their low cost and quantitative measurement capability. When a shank is selected as the IMU mounting position, an inverted pendulum model (IPM) can accurately estimate its spatial gait parameters. However, the stride-by-stride estimation of gait parameters using one IMU on each shank and the IPMs has not been validated. This study validated a spatial gait parameter estimation method using a shank-based IMU system. Spatial parameters were estimated via the double integration of the linear acceleration transformed by the IMU orientation information. To reduce the integral drift error, an IPM, applied with a linear error model, was introduced at the mid-stance to estimate the update velocity. the gait data of 16 healthy participants that walked normally and slowly were used. The results were validated by comparison with those extracted from an optical motion-capture system; the results showed strong correlation ( $$r>0.9$$ ) and good agreement with the gait metrics (stride length, stride velocity, and shank vertical displacement). In addition, the biases of the stride length and stride velocity extracted using the motion capture system were smaller in the IPM than those in the previous method using the zero-velocity-update. The error variabilities of the gait metrics were smaller in the IPM than those in the previous method. These results indicated that the reconstructed shank trajectory achieved a greater accuracy and precision than that of previous methods. This was attributed to the IPM, which demonstrates that shank-based IMU systems with IPMs can accurately reflect many spatial gait parameters including stride velocity.
Keywords
Funding Information
- JST CREST (JPMJCR1433)
This publication has 34 references indexed in Scilit:
- Unbiased and Mobile Gait Analysis Detects Motor Impairment in Parkinson's DiseasePLOS ONE, 2013
- Gait speed and gender effects on center of pressure progression during normal walkingGait & Posture, 2013
- Quantitative Normative Gait Data in a Large Cohort of Ambulatory Persons with Parkinson’s DiseasePLOS ONE, 2012
- Gait Event Detection on Level Ground and Incline Walking Using a Rate GyroscopeSensors, 2010
- Walking speed estimation using a shank-mounted inertial measurement unitJournal of Biomechanics, 2010
- Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term MonitoringIEEE Transactions on Biomedical Engineering, 2004
- The evolution of clinical gait analysisGait & Posture, 2002
- Comfortable and maximum walking speed of adults aged 20—79 years: reference values and determinantsAge and Ageing, 1997
- Stride length regulation in Parkinson's diseaseBrain, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986