Effect of different starting cadences on wingate anaerobic test indices in recreationally active males
- 10 April 2025
- journal article
- Published by SAGE Publications in Isokinetics and Exercise Science
- Vol. 33 (4) , 273-280
Abstract
Background: The lack of a standardized starting cadence for the acceleration phase makes comparing results challenging, in non-elite participants. Objective: The aim of this study was to determine the impact of different starting cadences on the Wingate Anaerobic Test (WAnT) indices. Methods: Twenty-four recreationally active males participated in the study. WAnT protocols consisting of different starting cadences of 60 (WAnT 60rpm ), 80 (WAnT 80rpm ), 100 (WAnT 100rpm ), and 120 rpm (WAnT 120rpm ) were randomly applied on different days. Differences between variables were determined using repeated measures ANOVA (LSD) analysis. An alpha value of p < 0.05 was considered significant. The effect size (ES) was calculated using Cohen's d. Results: WAnT 80rpm trial produced significantly higher peak power output (PPO) in comparison to WAnT 100rpm (WAnT 80rpm vs. WAnT 100rpm = 948 ± 129 W vs. 888 ± 112 W, p = 0.002, ES = 0.50) and WAnT 120rpm (WAnT 80rpm vs. WAnT 120rpm = 948 ± 129 W vs. 878 ± 139 W, p = 0.000, ES = 0.51) trials. The average power output (AvPO) values in the WAnT 60rpm and WAnT 80rpm trials were significantly higher than those in WAnT 100rpm (WAnT 60rpm vs. WAnT 100rpm = 592 ± 76.4 W vs. 574 ± 76.5 W, p = 0.001, ES = 0.23; WAnT 80rpm vs. WAnT 100rpm = 589 ± 83.9 W vs. 574 ± 76.5 W, p = 0.007, ES = 0.17) and WAnT 120rpm (WAnT 60rpm vs. WAnT 120rpm = 592 ± 76.4 W vs. 573 ± 85.3 W; p = 0.002, ES = 0.23; WAnT 80rpm vs. WAnT 120rpm = 589 ± 83.9 W vs. 573 ± 85.3 W, p = 0.007, ES = 0.18). Conclusions: This study suggests that starting the WAnT test when 60 or 80 rpm reached by recreationally active participants during the acceleration phase may be more suitable to achieve higher peak power and average power outputs. This study emphasizes the need to reconsider the standard starting cadence for the WAnT in anaerobically untrained individuals.Keywords
This publication has 30 references indexed in Scilit:
- Accuracy, reliability and segmental error relationship during a Wingate all-out testScience & Sports, 2022
- Optimal loads for a 30-s maximal power cycle ergometer test using a stationary startEuropean Journal of Applied Physiology, 2014
- The Wingate anaerobic test’s past and future and the compatibility of mechanically versus electro-magnetically braked cycle-ergometersEuropean Journal of Applied Physiology, 2006
- Assessment of peak power and short-term work capacityEuropean Journal of Applied Physiology, 2003
- Optimal pedalling velocity characteristics during maximal and submaximal cycling in humansEuropean Journal of Applied Physiology, 1999
- Optimal velocity for maximal power production in non-isokinetic cycling is related to muscle fibre type compositionEuropean Journal of Applied Physiology, 1996
- Muscle function during brief maximal exercise: accurate measurements on a friction-loaded cycle ergometerEuropean Journal of Applied Physiology, 1996
- Human Power Output and Muscle FatigueInternational Journal of Sports Medicine, 1994
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Load optimization for the wingate anaerobic testEuropean Journal of Applied Physiology, 1983