Comparison of Five Methods for Fit-Testing N95 Filtering-Facepiece Respirators
Authors:
- 1 October 2002
- journal article
- research article
- Published by Taylor & Francis in Applied Occupational and Environmental Hygiene
- Vol. 17 (10) , 723-730
Abstract
Five fit-testing methods (Bitrex, ambient aerosol condensation nuclei counter using the TSI PortaCount Plus, saccharin, modified ambient aerosol condensation nuclei counter using the TSI PortaCount Plus with the N95-Companion, and generated aerosol using corn oil) were evaluated for their ability to identify poorly fitting N95 filtering-facepiece respirators. Eighteen models of NIOSH-certified, N95 filtering-facepiece respirators were tested by a panel of 25 subjects using each fit-testing method. The penetration of the corn oil and the ambient aerosols through the filter media of each respirator was measured in order to adjust the corresponding generated and ambient aerosol overall fit factors, reflecting only face-seal leakage. Fit-testing results were compared to 5th percentiles of simulated workplace protection factors. Beta errors (the chance of passing a fit-test in error) ranged from 3 percent to 11 percent. Alpha errors (the chance of failing a fit-test in error) ranged from 51 percent to 84 percent. The ambient aerosol using the TSI PortaCount Plus and the generated aerosol methods identified poorly fitting respirators better than the saccharin, the Companion, and Bitrex methods. These errors rates should be considered when selecting a fit-testing method for fitting N95 filtering-facepieces. When both types of errors were combined as an assignment error, the ambient aerosol method using the TSI PortaCount Plus had the lowest percentage of wearers being assigned a poor-fitting respirator.Keywords
This publication has 9 references indexed in Scilit:
- Statistical Methods for Rates and Proportions2003
- Respiratory Protection as a Function of Respirator Fitting Characteristics and Fit-Test AccuracyAIHA Journal, 2001
- Capability of Respirator Wearers to Detect Aerosolized Qualitative Fit Test Agents (Sweetener and Bitrex) with Known Fixed LeaksApplied Occupational and Environmental Hygiene, 2000
- Comparison of Six Respirator Fit-Test Methods with an Actual Measurement of Exposure in a Simulated Health Care Environment: Part II — Method Comparison TestingAIHA Journal, 1998
- Workplace Protection Factor Measurements on Powered Air-Purifying Respirators at a Secondary Lead Smelter: Results and DiscussionAIHA Journal, 1984
- ASSIGNED PROTECTION FACTORS FOR TWO RESPIRATOR TYPES BASED UPON WORKPLACE PERFORMANCE TESTINGAnnals of Occupational Hygiene, 1984
- PERFORMANCE MEASUREMENTS ON A POWERED AIR-PURIFYING RESPIRATOR MADE DURING ACTUAL FIELD USE IN A SILICA BAGGING OPERATIONAnnals of Occupational Hygiene, 1983
- Statistics1977
- Predictive Value of a Single Diagnostic Test in Unselected PopulationsNew England Journal of Medicine, 1966