Intermuscular technique for implantation of the subcutaneous implantable cardioverter defibrillator: long-term performance and complications
Authors:
- 1 December 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 19 (12) , 2036-2041
Abstract
The subcutaneous cardioverter defibrillator was designed to overcome electrode complications of transvenous defibrillation systems. While largely achieved, pocket complications have increased. Subcutaneous implantation of the pulse generator leaves it prone to erosion, extrusion, discomfort, and poor cosmesis. We use a demonstration electrode and pulse generator with fluoroscopy, prior to prepping and draping, to maximize the left ventricular mass between them. We adapted a submuscular abdominal ICD technique to implant the S-ICD intermuscularly between the anterior surface of serratus anterior and the posterior surface of latissimus dorsi. Surgery in our patients beyond the subcutaneous tissue was bloodless, as muscle layers were carefully separated but not incised, which also protected the long thoracic nerve. Two layers of muscle protect the pulse generator. We have implanted 82 consecutive patients with this technique, taking ∼65 min. All patients were converted with 65 J standard polarity shock during induced arrhythmia conversion testing, with six (7.3%) patients requiring a repositioning of the pulse generator prior to successful conversion. Seven spontaneous episodes of ventricular fibrillation were detected in three (3.6%) patients, all successfully converted back to sinus rhythm. Long-term patient outcomes have been good with low complication rates over the mean ± standard deviation 3.6 ± 1.2 years. Our intermuscular technique and implant methodology is successful for placement of the subcutaneous defibrillator pulse generator. Our technique leads to an excellent cosmetic result and high levels of patient satisfaction. Rates of first shock conversion during defibrillation testing, inappropriate shocks, and complications during follow-up compare favourably with previous published case series. There were no left arm movement limitations post-operatively.Keywords
This publication has 15 references indexed in Scilit:
- Safety and Efficacy of the Totally Subcutaneous Implantable DefibrillatorJACC, 2015
- Pocket infection as a complication of a subcutaneous implantable cardioverter-defibrillatorInternational Journal of Cardiology, 2014
- Shoulder Joint Dislocation as an Unusual Complication of Defibrillation Threshold Testing Following Subcutaneous Implantable Cardioverter-Defibrillator ImplantationIndian Pacing and Electrophysiology Journal, 2014
- Subcutaneous Implantable Cardioverter-Defibrillators and Sternal WiresCirculation: Arrhythmia and Electrophysiology, 2014
- Outcome After Implantation of a Cardioverter-Defibrillator in Patients With Brugada SyndromeCirculation, 2013
- Clinical Experience of Subcutaneous and Transvenous Implantable Cardioverter Defibrillators in Children and TeenagersPacing and Clinical Electrophysiology, 2013
- United Kingdom national experience of entirely subcutaneous implantable cardioverter-defibrillator technology: important lessons to learnEP Europace, 2013
- The Entirely Subcutaneous Implantable Cardioverter-DefibrillatorJACC, 2012
- Clinical experience of entirely subcutaneous implantable cardioverter-defibrillators in children and adults: cause for cautionEuropean Heart Journal, 2012
- Implantable Cardioverter-Defibrillator Lead PerformanceCirculation, 2008