Abstract
This study investigated a BaO- and PbO-doped borosilicate glass system in the low energy region (15–47.04 keV) in terms of the radiation shielding properties. At 47.04 keV, the glasses’ linear attenuation coefficient values are 25.039, 33.557, and 42.165 cm −1 for glasses with densities of 4.038, 4.555, and 5.071 g cm −3 . The study determined the ratio of the half value layer (HVL) value to the least and most BaO/PbO content, and the results showed that the ratio remained above one, meaning that the more BaO/PbO is introduced into the glasses, the smaller its HVL. The tenth value layer values were found to follow the order of S1 > S2 > S3. Additionally, the glasses’ effective atomic number values correlated with the content of these heavy metal oxides, as the B 2 O 3 that these HMOs are replacing has a smaller atomic number than Pb and Ba. Overall, the borosilicate glasses were found to have good attenuation properties across the tested low energy region, with further enhancements in characteristics when introducing more PbO and BaO into the glasses at the expense of B 2 O 3 . The results in this study provide insights that can be applied in medical imaging, X-ray rooms and health radiation protection.
Funding Information
  • Princess Nourah Bint Abdulrahman University ((RPFAP-48- 1445))

This publication has 34 references indexed in Scilit: