Abstract
Introduction: The primary criterion to validate maximum oxygen consumption ( V ˙ O 2max ) is the plateau of oxygen consumption ( V ˙ O 2plat ), a point where oxygen consumption levels off and stops increasing, even when the workload continues to rise. Although a uniformly agreed-upon definition and guidelines for the assessment of V ˙ O 2plat do not exist. Therefore, this study aimed to compare the V ˙ O 2plat achieved using a criterion based on each participant’s V ˙ O 2 change per workload increment with the most used fixed criterion for assessing V ˙ O 2max . Furthermore, the study intended to demonstrate the consequences of relying solely on V ˙ O 2plat to confirm a maximal effort. Methods: Thirty-five physically active males (26.7 ± 6.3 years) performed two maximal treadmill protocols separated by a week: using one-minute (1-MIN) and three-minute (3-MIN) stages, both increasing 1 km·h -1 per stage. V ˙ O 2max was defined when a V ˙ O 2plat was established between the two consecutive highest 30 s sampling periods, using: 1) Δ V ˙ O 2 ≤ 50% of the individual submaximal V ˙ O 2 /speed slope (IND- V ˙ O 2plat ); 2) Δ V ˙ O 2 ≤150 mL·min -1 (FIXED- V ˙ O 2plat ). Results: V ˙ O 2plat were identified in 85.7% to 97.1% of the tests. No differences were observed between the criteria and protocols in meeting the V ˙ O 2plat . The mean V ˙ O 2 /speed slope differed significantly across protocols (p=0.001), indicating that the 3-MIN stage protocols elicited a greater V ˙ O 2 internal response to the increments than the 1-MIN stages (236.51 ± 56.44 mL·min -1 and 214.21 ± 44.81 mL.min -1 , respectively). 1-MIN protocols achieved higher aerobic power than 3-MIN protocols, regardless of the criterion used. Specifically, using IND- V ˙ O 2plat , 1-MIN values were 4121.93 ± 516.95 mL·min -1 vs. 3-MIN 3950.47 ± 550.28 mL·min -1 (p=0.002); using FIXED- V ˙ O 2plat , 1-MIN values were 4107.21 ± 521.90 mL·min -1 vs. 3-MIN 3953.91 ± 534.16 mL·min -1 (p=0.001). No differences were identified in V ˙ O 2max despite of whether a V ˙ O 2plat was attained (concordant and discordant classifications) (p ≤ 0.05). Discussion: The incidence of V ˙ O 2plat seems to be independent of the criteria used; however, the fixed criterion does not fully account for individual responses to the external load, which do vary according to protocol design. Additionally, the V ˙ O 2max remains unaltered by the presence of a plateau. Therefore, a different methodological approach needs to be employed to provide a more nuanced validation of the V ˙ O 2max attainment.

This publication has 42 references indexed in Scilit: