A dosimetric uncertainty analysis for photon‐emitting brachytherapy sources: Report of AAPM Task Group No. 138 and GEC‐ESTRO
Authors:
Top Cited Papers
- 14 January 2011
- journal article
- Published by Wiley in Medical Physics
- Vol. 38 (2) , 782-801
Abstract
This report addresses uncertainties pertaining to brachytherapy single‐source dosimetry preceding clinical use. The International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement (GUM) and the National Institute of Standards and Technology (NIST) Technical Note 1297 are taken as reference standards for uncertainty formalism. Uncertainties in using detectors to measure or utilizing Monte Carlo methods to estimate brachytherapy dose distributions are provided with discussion of the components intrinsic to the overall dosimetric assessment. Uncertainties provided are based on published observations and cited when available. The uncertainty propagation from the primary calibration standard through transfer to the clinic for air‐kerma strength is covered first. Uncertainties in each of the brachytherapy dosimetry parameters of the TG‐43 formalism are then explored, ending with transfer to the clinic and recommended approaches. Dosimetric uncertainties during treatment delivery are considered briefly but are not included in the detailed analysis. For low‐ and high‐energy brachytherapy sources of low dose rate and high dose rate, a combined dosimetric uncertainty is estimated, which is consistent with prior literature estimates. Recommendations are provided for clinical medical physicists, dosimetry investigators, and source and treatment planning system manufacturers. These recommendations include the use of the GUM and NIST reports, a requirement of constancy of manufacturer source design, dosimetry investigator guidelines, provision of the lowest uncertainty for patient treatment dosimetry, and the establishment of an action level based on dosimetric uncertainty. These recommendations reflect the guidance of the American Association of Physicists in Medicine (AAPM) and the Groupe Européen de Curiethérapie–European Society for Therapeutic Radiology and Oncology (GEC‐ESTRO) for their members and may also be used as guidance to manufacturers and regulatory agencies in developing good manufacturing practices for sources used in routine clinical treatments.Keywords
This publication has 71 references indexed in Scilit:
- The IPEM code of practice for determination of the reference air kerma rate for HDR192Ir brachytherapy sources based on the NPL air kerma standardPhysics in Medicine & Biology, 2010
- Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energiesMedical Physics, 2010
- In Vivo Dosimetry Using a Linear Mosfet-Array Dosimeter to Determine the Urethra Dose In 125I Permanent Prostate ImplantsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Comparison of air kerma standards of LNE–LNHB and NPL for192Ir HDR brachytherapy sources: EUROMET project no 814Physics in Medicine & Biology, 2008
- Comparison of dosimetric standards of USA and France for HDR brachytherapyPhysics in Medicine & Biology, 2005
- Dosimetric evaluation of GAFCHROMIC® XR type T and XR type R filmsJournal of Applied Clinical Medical Physics, 2005
- New national air-kerma-strength standards for I-125 and Pd-103 brachytherapy seedsJournal of Research of the National Institute of Standards and Technology, 2003
- The use of a reflective scanner to study radiochromic film responsePhysics in Medicine & Biology, 2002
- Sifting the evidence---what's wrong with significance tests? Another comment on the role of statistical methodsBMJ, 2001
- Clinical dosimetry using mosfetsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1997