Electrical Characterization of 3D Au Microelectrodes for Use in Retinal Prostheses
Open Access
- 17 June 2015
- Vol. 15 (6) , 14345-14355
Abstract
In order to provide high-quality visual information to patients who have implanted retinal prosthetic devices, the number of microelectrodes should be large. As the number of microelectrodes is increased, the dimensions of each microelectrode must be decreased, which in turn results in an increased microelectrode interface impedance and decreased injection current dynamic range. In order to improve the trade-off envelope between the number of microelectrodes and the current injection characteristics, a 3D microelectrode structure can be used as an alternative. In this paper, the electrical characteristics of 2D and 3D Au microelectrodes were investigated. In order to examine the effects of the structural difference, 2D and 3D Au microelectrodes with different base areas but similar effective surface areas were fabricated and evaluated. Interface impedances were measured and similar dynamic ranges were obtained for both 2D and 3D Au microelectrodes. These results indicate that more electrodes can be implemented in the same area if 3D designs are used. Furthermore, the 3D Au microelectrodes showed substantially enhanced electrical durability characteristics against over-injected stimulation currents, withstanding electrical currents that are much larger than the limit measured for 2D microelectrodes of similar area. This enhanced electrical durability property of 3D Au microelectrodes is a new finding in microelectrode research, and makes 3D microelectrodes very desirable devices.Keywords
This publication has 18 references indexed in Scilit:
- Design, Fabrication and Characterization of a Low-Impedance 3D Electrode Array System for Neuro-ElectrophysiologySensors, 2012
- A Novel In Vitro Sensing Configuration for Retinal Physiology Analysis of a Sub-Retinal ProsthesisSensors, 2012
- Subretinal electronic chips allow blind patients to read letters and combine them to wordsProceedings Of The Royal Society B-Biological Sciences, 2010
- Neural Stimulation and Recording ElectrodesAnnual Review of Biomedical Engineering, 2008
- Electrical properties of retinal–electrode interfaceJournal of Neural Engineering, 2007
- Fabrication of pyramid shaped three-dimensional 8×8 electrodes for artificial retinaSensors and Actuators A: Physical, 2006
- Simulation of Artificial Vision, III: Do the Spatial or Temporal Characteristics of Stimulus Pixelization Really Matter?Investigative Ophthalmology & Visual Science, 2005
- Retinal remodeling during retinal degenerationExperimental Eye Research, 2005
- Can subretinal microphotodiodes successfully replace degenerated photoreceptors?Vision Research, 1999
- Bipolar Surface Electrical Stimulation of the Vertebrate RetinaArchives of Ophthalmology (1950), 1994