Abstract
In this paper incremental inductance approach is used for static eccentricity detection under offline condition. This method uses the DC values of q-axis voltage that makes it independent of the bandwidth of the controller. In this work a new feature, height of hump of the incremental inductance curve, along with the known feature, saturation current in d-axis, was used for fault detection. It is shown that this new feature is independent of the machine operating temperature that makes the method robust with respect to machine operating temperature. It is also shown that the proposed method is robust to the rotor position misalignment. A new controller for off-line testing was designed that controls both the speed and saturation of the machine. Using this controller the hardware requirements for constant rotation of the machine are reduced, while keeping the method independent of the bandwidth of the controller. Finally, a Matlab based computer program was developed to calculate the features: saturation current in d-axis and height of hump, of the incremental inductance curve. Six different machines, combinations of two stators and three rotors, were used to validate the proposed method through experiments.

This publication has 18 references indexed in Scilit: