Abstract
Purpose. Development of a simple, phantom-based methodology allowing for pilot applications for the Elements TPS cranio-vascular module and clinical implementation prior to AVM treatments. Methods. A customized phantom was developed to be visible in MRI and CT images. High resolution digital subtraction angiograms (DSAs) and CT images of the phantom were acquired and imported into the Brainlab Elements treatment planning system. A clinical treatment plan with 5 arcs was generated in cranial vascular planning module and delivered to the phantom using a Varian TrueBeam STx Linac equipped with HD-MLCs and Brainlab ExacTrac imaging system for non-coplanar setup verification. The delivered dose was verified using a calibrated ionization chamber placed in the phantom. Upon verification of the TPS workflow, three patients with AVM who have been treated to date at our center using the Brainlab’s cranial vascular module for AVM are presented here for retrospective review. Results. The difference between the planed and measured dose by the ionization chamber was found to be less than 1%. Following a successful dose verification study, a clinical workflow was created. Currently, three AVM patients have been treated successfully. Clinical aspects of imaging and treatment planning consideration are presented in retrospective setting. Conclusions. Dose verification of the Brainlab Elements cranial vascular planning module for intracranial SRS treatments of AVM on Varian TrueBeam was successfully implemented using a custom-made phantom with <1% discrepancy. The Brainlab Elements’ cranial vascular module was successfully implemented in clinical workflow to treat patients with AVM. This manuscript provides a guideline for clinical implementation of frameless Linac-based AVM treatment using the Brainlab Elements TPS.Keywords
This publication has 21 references indexed in Scilit:
- Endovascular Advances for Brain Arteriovenous MalformationsNeurosurgery, 2014
- Surgical and radiosurgical results of the treatment of cerebral arteriovenous malformationsJournal of Clinical Neuroscience, 2012
- Radiochirurgie stéréotaxique des malformations artérioveineuses cérébralesCancer/Radiothérapie, 2012
- Frameless linac-based stereotactic radiosurgery (SRS) for brain metastases: analysis of patient repositioning using a mask fixation system and clinical outcomesRadiation Oncology, 2011
- Endovascular treatment of brain arteriovenous malformations with prolonged intranidal Onyx injection technique: long-term results in 350 consecutive patients with completed endovascular treatment courseJournal of Neurosurgery, 2011
- Feasibility, safety, and outcome of frameless image-guided robotic radiosurgery for brain metastasesJournal of Neuro-Oncology, 2009
- Use of the BrainLAB ExacTrac X-Ray 6D System in Image-Guided RadiotherapyMedical Dosimetry, 2008
- Simple Risk Predictions for Arteriovenous Malformation HemorrhageNeurosurgery, 1995
- Stereotactic radiosurgery for arteriovenous malformations of the brainJournal of Neurosurgery, 1991
- Angiographic Follow-up Study of Cerebral Arteriovenous Malformations with Reference to Their Enlargement and RegressionNeurosurgery, 1989