The fast industrialization and constant improvement in the living conditions of individuals have prompted development rate in the utilization of refrigeration and cooling frameworks all through the world alongside India specifically. The normal home appliance used for the storage of food, drugs, and different products to shield them from decay is the refrigerator. The general refrigerant which is utilized in India taking everything into account is R-134a, which is a HFC (Hydro Fluorocarbon), considering its excellent thermodynamic and physical properties. But R-134a has a high value GWP (Global Warming Potential) of 1300. Lot of research is underway to find an alternative refrigerant which is eco-friendly. The use of HC (Hydrocarbons) like CARE-30, which is a combination of propane (R-290) and iso-butane (R-600a) is one such case. Apart from this, the previous studies have shown that by adding nanoparticles to the refrigerant, will enhance performance of the Vapour compression refrigeration system. This paper presents a comparative analysis of the Vapor compression refrigeration system by conducting experiment using CARE-30 refrigerant and CARE-30 mixed with Al2O3 nanoparticles separately.