Run‐Specific Limits of Detection and Quantitation for STR‐based DNA Testing
Authors:
- 7 December 2006
- journal article
- Published by Wiley in Journal of Forensic Sciences
- Vol. 52 (1) , 97-101
Abstract
STR‐based DNA profiling is an exceptionally sensitive analytical technique that is often used to obtain results at the very limits of its sensitivity. The challenge of reliably distinguishing between signal and noise in such situations is one that has been rigorously addressed in numerous other analytical disciplines. However, an inability to determine accurately the height of electropherogram baselines has caused forensic DNA profiling laboratories to utilize alternative approaches. Minimum thresholds established during laboratory validation studies have become the de facto standard for distinguishing between reliable signal and noise/technical artifacts. These minimum peak height thresholds generally fail to consider variability in the sensitivity of instruments, reagents, and the skill of human analysts involved in the DNA profiling process over the course of time. Software (BatchExtract) made publicly available by the National Center for Biotechnology Information now provides an alternative means of establishing limits of detection and quantitation that is more consistent with those used in other analytical disciplines. We have used that software to determine the height of each data collection point for each dye along a control sample's electropherogram trace. These values were then used to determine a limit of detection (the average amount of background noise plus three standard deviations) and a limit of quantitation (the average amount of background noise plus 10 standard deviations) for each control sample. Analyses of the electropherogram data associated with the positive, negative, and reagent blank controls included in 50 different capillary electrophoresis runs validate that this approach could be used to determine run‐specific thresholds objectively for use in forensic DNA casework.Keywords
This publication has 8 references indexed in Scilit:
- STR DNA Typing: Increased Sensitivity and Efficient Sample Consumption Using Reduced PCR Reaction VolumesJournal of Forensic Sciences, 2003
- AmpFℓSTR® Profiler Plus™ Short Tandem Repeat DNA Analysis of Casework Samples, Mixture Samples, and Nonhuman DNA Samples Amplified under Reduced PCR Volume Conditions (25 µL)Journal of Forensic Sciences, 2003
- Validation of STR Typing by Capillary ElectrophoresisJournal of Forensic Sciences, 2001
- DNA fingerprinting from single cellsNature, 1997
- DNA fingerprints from fingerprintsNature, 1997
- Characterization of Human Lymphoid Cell Lines GM9947 and GM9948 as Intra- and Interlaboratory Reference Standards for DNA TypingGenomics, 1995
- Limit of detection (LQD)/limit of quantitation (LOQ): comparison of the empirical and the statistical methods exemplified with GC-MS assays of abused drugsClinical Chemistry, 1994
- Determination of the lower limit of detection.Clinical Chemistry, 1989