Experimental investigation on the cyclic performance of perfobond rib shear connectors
Authors:
- 14 July 2020
- journal article
- research article
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 23 (16) , 3509-3524
Abstract
The behavior of perfobond rib shear connectors (PBL shear connectors) under monotonic loading has been widely studied. However, the performance of these connectors under cyclic loading is poorly understood and has seldom been investigated. This work presents an experimental study focusing on the cyclic performance of representative PBL shear connectors with passing rebar. Optical fibers were introduced to measure the detailed strain distributions. Results showed that the bearing capacity of these connectors could reduce up to 55.04% when compared with that under monotonic loading. The performance of these connectors differed significantly between the pull and push directions in the cyclic loading process. The concrete cracks, relative slip, and strains were developed earlier and more completely under pull than under push. Furthermore, rapid stiffness degradation, severe cracking and deformation of the concrete dowels were revealed, indicating the rapid failure of the adhesive effect, reduction of both the shear-friction effect and the dowel action of the passing rebars. These factors all contributed to the observed significant cyclic deterioration of the peak load and the slip. Based on this, a modified formula was proposed to consider the reduction effect. Comparisons between the analytical solution and test results validated the formula.Keywords
Funding Information
- Sichuan Provincial Science and Technology Support Program (2019YFH0139)
- National Natural Science Foundation of China (51708466)
This publication has 26 references indexed in Scilit:
- Parametric study on shear capacity of circular-hole and long-hole perfobond shear connectorJournal of Constructional Steel Research, 2016
- Estimation of the cyclic capacity of beam-to-column dowel connections in precast industrial buildingsBulletin of Earthquake Engineering, 2014
- Perforated shear connectors on composite girders under monotonic loading: An experimental approachEngineering Structures, 2013
- Experimental study of Perfobond shear connectors in composite constructionJournal of Constructional Steel Research, 2013
- Cyclic Performances of Shear Connectors2011
- Behavior of beams with dowel actionEngineering Structures, 2007
- Resistance of headed studs subjected to fatigue loadingJournal of Constructional Steel Research, 2007
- Perforated shear connectorsSteel and Composite Structures, 2002
- Behavior of Composite Bridge Decks with Alternative Shear ConnectorsJournal of Bridge Engineering, 2001
- Experimental study on stud shear connectors subjected to cyclic loadingJournal of Constructional Steel Research, 1996