A comparison of hallux valgus angles assessed with computerised plantar pressure measurements, clinical examination and radiography in patients with diabetes
Open Access
- 1 January 2014
- journal article
- Published by Wiley in Journal of Foot and Ankle Research
- Vol. 7 (1) , 33
Abstract
Background: Hallux valgus deformity is a common musculoskeletal foot disorder with a prevalence of 3.5% in adolescents to 35.7% in adults aged over 65 years. Radiographic measurements of hallux valgus angles (HVA) are considered to be the most reproducible and accurate assessment of HVA. However, in European countries, many podiatrists do not have direct access to radiographic facilities. Therefore, alternative measurements are desired. Such measurements are computerised plantar pressure measurement and clinical goniometry. The purpose of this study was to establish the agreement of these techniques and radiographic assessments.Methods: HVA was determined in one hundred and eighty six participants suffering from diabetes. Radiographic measurements of HVA were performed with standardised static weight bearing dorsoplantar foot radiographs.The clinical goniometry for HVA was measured with a universal goniometer. Computerised plantar pressure measurement for HVA was executed with the EMED SF‐4® pressure platform and Novel‐Ortho‐Geometry software. The intra‐class correlation coefficients (ICC) and levels of agreement were analysed using Bland & Altman plots.Results: Comparison of radiographic measurements to clinical goniometry for HVA showed an intraclass correlation coefficient (ICC) of 0.81 (95% confidence interval, 0.76 to 0.86; p). Radiographic measurement versus computerised plantar pressure measurement showed an ICC of 0.59 (95% confidence interval, 0.49 to 0.68; p). In addition, clinical goniometry versus computerised plantar pressure measurement showed an ICC of 0.77 (95% confidence interval, 0.70 to 0.82; p). The systematic difference of the computerised plantar pressure measurement compared with radiographic measurement and clinical goniometry was 7.0 degrees (SD 6.8) and 5.2 degrees (SD 5.0), respectively. The systemic difference of radiographic measurements compared with clinical goniometry was 1.8 degrees (SD 5.0).Conclusions: The agreement of computerised plantar pressure measurement and clinical goniometry for HVA compared to radiographic measurement of HVA is unsatisfactory. Radiographic measurements of HVA and clinical goniometry for HVA yield better agreement compared to radiographic measurements and computerised plantar pressure measurement. The traditional radiographic measurement techniques are strongly recommended for the assessment of HVA.Keywords
This publication has 53 references indexed in Scilit:
- Test–retest reliability of dynamic plantar loading and foot geometry measures in diabetics with peripheral neuropathyGait & Posture, 2013
- Prevalence of hallux valgus in the general population: a systematic review and meta‐analysisJournal of Foot and Ankle Research, 2010
- Combined rotation scarf and Akin osteotomies for hallux valgus: a patient focussed 9 year follow up of 50 patientsJournal of Foot and Ankle Research, 2010
- A geometric analysis of hallux valgus: correlation with clinical assessment of severityJournal of Foot and Ankle Research, 2009
- Radiographic validation of the Manchester scale for the classification of hallux valgus deformityRheumatology, 2005
- Die Prävalenz von Beschwerden und Deformierungen des Fußes bei AdoleszentenZeitschrift für Orthopädie und ihre Grenzgebiete, 2004
- Reliability of Standard Foot Radiographic MeasurementsFoot & Ankle International, 1994
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Hallux Valgus Assessment: Report of Research Committee of American Orthopaedic Foot and Ankle SocietyFoot & Ankle, 1984
- Radiographic Measurements of the Normal Adult FootFoot & Ankle, 1980