External validation of BIA equations to estimate appendicular skeletal muscle mass in older adults: Importance of the bias analysis and derivation of correction factors to achieve agreement
Open Access
- 25 August 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Nutrition
- Vol. 9, 951346
Abstract
There are several equations based on bioelectrical impedance analysis (BIA) to estimate with high precision appendicular skeletal muscle mass (ASM). However, most of the external validation studies have reported that these equations are inaccurate or biased when applied to different populations. Furthermore, none of the published studies has derived correction factors (CFs) in samples of community-dwelling older adults, and none of the published studies have assessed the influence of the dual-energy X-ray absorptiometry (DXA) model on the validation process. This study assessed the agreement between six BIA equations and DXA to estimate ASM in non-Caucasian older adults considering the DXA model and proposed a CF for three of them. This analysis included 547 non-institutionalized subjects over 60 years old from the northwest of Mexico who were physically independent and without cognitive impairment: 192 subjects were measured using DXA Hologic, while 355 were measured by DXA Lunar. The agreement between each of the equations and DXA was tested considering the DXA model used as a reference method for the design of each equation, using the Bland and Altman procedure, a pairedttest, and simple linear regression as objective tests. This process was supported by the differences reported in the literature and confirmed in a subsample of 70 subjects measured with both models. Only six published BIA equations were included. The results showed that four equations overestimated ASMDXA, and two underestimated it (p< 0.001, 95% CI for Kim's equation:−5.86-−5.45, Toselli's:−0.51-−0.15, Kyle's: 1.43–1.84, Rangel-Peniche's: 0.32–0.74, Sergi's: 0.83–1.23, and Yoshida's: 4.16–4.63 kg). However, Toselli's, Kyle's and Rangel-Peniche's equations were the only ones that complied with having a homogeneous bias. This finding allowed the derivation of CFs, which consisted of subtracting or adding the mean of the differences from the original equation. After estimating ASM applying the respective CF, the new ASM estimations showed no significant bias and its distribution remained homogeneously distributed. Therefore, agreement with DXA in the sample of non-Caucasian was achieved. Adding valid CFs to some BIA equations allowed to reduce the bias of some equations, making them valid to estimate the mean values of ASM at group level.Keywords
This publication has 61 references indexed in Scilit:
- A multinational study to develop universal standardization of whole-body bone density and composition using GE Healthcare Lunar and Hologic DXA systemsJournal of Bone and Mineral Research, 2012
- Regional Body Composition: Cross‐calibration of DXA Scanners—QDR4500W and Discovery WiObesity, 2010
- Body Composition Measured by Dual‐energy X‐ray Absorptiometry Half‐body Scans in Obese AdultsObesity, 2009
- Body composition in the elderly: Reference values and bioelectrical impedance spectroscopy to predict total body skeletal muscle massClinical Nutrition, 2009
- Comparison of body weight and composition measured by two different dual energy X-ray absorptiometry devices and three acquisition modes in obese womenClinical Nutrition, 2006
- Body composition analysis by dual X‐ray absorptiometry:in vivoandin vitrocomparison of three different fan‐beam instrumentsScandinavian Journal of Clinical and Laboratory Investigation, 2006
- Bioelectrical impedance analysis—part II: utilization in clinical practiceClinical Nutrition, 2004
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- “Mini-mental state”Journal of Psychiatric Research, 1975
- Assessment of Older People: Self-Maintaining and Instrumental Activities of Daily LivingThe Gerontologist, 1969