Abstract
Large university campuses need timely, privacy-conscious information about how indoor spaces are used in order to improve space management, energy efficiency, and operational responsiveness. Yet many indoor positioning solutions still depend on additional hardware such as Bluetooth Low Energy beacons, ultra-wideband anchors, or camera-based sensing, which increases deployment cost and maintenance complexity. This paper presents a lightweight campus occupancy analysis and indoor localization framework that reuses an existing Cisco Wireless LAN Controller (WLC) infrastructure as a sensing layer. The system retrieves received signal strength indicator (RSSI) observations from access points over secure SSH sessions, converts these observations into approximate distance estimates through a calibrated log-distance path loss model, and computes user positions using weighted non-linear least-squares multilateration (Mlat). In addition to point localization, the framework generates occupancy heatmaps, cumulative reliability curves, and access-point-density sensitivity analyses based on a 50 m × 50 m evaluation scenario with 500 randomized samples. To support privacy-preserving deployment, the service layer exposes only zone-level occupancy information and omits personally identifiable network identifiers. The results indicate that Wi-Fi-based localization can provide cost-effective and scalable occupancy intelligence with sufficient accuracy for campus-wide density monitoring and smart building applications.×

This publication has 7 references indexed in Scilit: